Filtered by vendor Schneider-electric
                        
                        Subscribe
                        
                        
                    
                    
                
                    Total
                    758 CVE
                
            | CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 | 
|---|---|---|---|---|---|
| CVE-2013-0663 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | 6.8 MEDIUM | N/A | 
| Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials. | |||||
| CVE-2011-5163 | 2 Mitsubishi-automation, Schneider-electric | 2 Mx4 Scada, Citectscada | 2025-04-11 | 4.6 MEDIUM | N/A | 
| Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence. | |||||
| CVE-2013-0655 | 1 Schneider-electric | 1 Software Update Utility | 2025-04-11 | 9.3 HIGH | N/A | 
| The client in Schneider Electric Software Update (SESU) Utility 1.0.x and 1.1.x does not ensure that updates have a valid origin, which allows man-in-the-middle attackers to spoof updates, and consequently execute arbitrary code, by modifying the data stream on TCP port 80. | |||||
| CVE-2011-3330 | 1 Schneider-electric | 6 Monitor Pro, Opc Factory Server, Pl7 Pro and 3 more | 2025-04-11 | 7.2 HIGH | N/A | 
| Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter. | |||||
| CVE-2011-3144 | 2 Aveva, Schneider-electric | 3 Clearscada, Scx 67, Scx 68 | 2025-04-11 | 4.3 MEDIUM | N/A | 
| Cross-site scripting (XSS) vulnerability in Control Microsystems ClearSCADA 2005, 2007, and 2009 before R2.3 and R1.4, as used in SCX before 67 R4.5 and 68 R3.9, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
| CVE-2013-0658 | 1 Schneider-electric | 1 Accutech Manager | 2025-04-11 | 10.0 HIGH | N/A | 
| Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request. | |||||
| CVE-2013-0657 | 1 Schneider-electric | 1 Interactive Graphical Scada System | 2025-04-11 | 10.0 HIGH | N/A | 
| Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol. | |||||
| CVE-2012-1990 | 1 Schneider-electric | 2 Kerweb, Kerwin | 2025-04-11 | 4.3 MEDIUM | N/A | 
| Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields. | |||||
| CVE-2013-2824 | 1 Schneider-electric | 4 Citectscada, Powerlogic Scada, Struxureware Powerscada Expert and 1 more | 2025-04-11 | 7.8 HIGH | N/A | 
| Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet. | |||||
| CVE-2012-0930 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2025-04-11 | 4.3 MEDIUM | 6.1 MEDIUM | 
| Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||
| CVE-2013-2796 | 1 Schneider-electric | 3 Citectscada, Powerlogic Scada, Vijeo Citect | 2025-04-11 | 6.9 MEDIUM | N/A | 
| Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue. | |||||
| CVE-2013-0664 | 1 Schneider-electric | 3 Modicon M340, Modicon Premium, Modicon Quantum Plc | 2025-04-11 | 8.5 HIGH | N/A | 
| The FactoryCast service on the Schneider Electric Quantum 140NOE77111 and 140NWM10000, M340 BMXNOE0110x, and Premium TSXETY5103 PLC modules allows remote authenticated users to send Modbus messages, and consequently execute arbitrary code, by embedding these messages in SOAP HTTP POST requests. | |||||
| CVE-2012-0931 | 1 Schneider-electric | 1 Modicon Quantum Plc | 2025-04-11 | 7.5 HIGH | 9.8 CRITICAL | 
| Schneider Electric Modicon Quantum PLC does not perform authentication between the Unity software and PLC, which allows remote attackers to cause a denial of service or possibly execute arbitrary code via unspecified vectors. | |||||
| CVE-2011-4859 | 1 Schneider-electric | 21 M340 Ethernet Module Bmxnoe0100, M340 Ethernet Module Bmxnoe0110, M340 Ethernet Module Bmxp342020 and 18 more | 2025-04-11 | 10.0 HIGH | N/A | 
| The Schneider Electric Quantum Ethernet Module, as used in the Quantum 140NOE771* and 140CPU65* modules, the Premium TSXETY* and TSXP57* modules, the M340 BMXNOE01* and BMXP3420* modules, and the STB DIO STBNIC2212 and STBNIP2* modules, uses hardcoded passwords for the (1) AUTCSE, (2) AUT_CSE, (3) fdrusers, (4) ftpuser, (5) loader, (6) nic2212, (7) nimrohs2212, (8) nip2212, (9) noe77111_v500, (10) ntpupdate, (11) pcfactory, (12) sysdiag, (13) target, (14) test, (15) USER, and (16) webserver accounts, which makes it easier for remote attackers to obtain access via the (a) TELNET, (b) Windriver Debug, or (c) FTP port. | |||||
| CVE-2013-0687 | 1 Schneider-electric | 1 Micom S1 Studio | 2025-04-11 | 6.6 MEDIUM | N/A | 
| The installer routine in Schneider Electric MiCOM S1 Studio uses world-writable permissions for executable files, which allows local users to modify the service or the configuration files, and consequently gain privileges or trigger incorrect protective-relay operation, via a Trojan horse executable file. | |||||
| CVE-2011-4034 | 1 Schneider-electric | 3 Citecthistorian, Citectscada Reports, Vijeo Historian | 2025-04-11 | 9.3 HIGH | N/A | 
| Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors. | |||||
| CVE-2011-4860 | 1 Schneider-electric | 3 Quantum Ethernet Module 140noe77100, Quantum Ethernet Module 140noe77101, Quantum Ethernet Module 140noe77111 | 2025-04-11 | 10.0 HIGH | N/A | 
| The ComputePassword function in the Schneider Electric Quantum Ethernet Module on the NOE 771 device (aka the Quantum 140NOE771* module) generates the password for the fwupgrade account by performing a calculation on the MAC address, which makes it easier for remote attackers to obtain access via a (1) ARP request message or (2) Neighbor Solicitation message. | |||||
| CVE-2013-2761 | 1 Schneider-electric | 1 Modicon M340 | 2025-04-11 | 4.0 MEDIUM | N/A | 
| The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client. | |||||
| CVE-2023-25619 | 1 Schneider-electric | 14 Bmeh58s, Bmeh58s Firmware, Bmep58s and 11 more | 2025-02-05 | N/A | 7.5 HIGH | 
| A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. | |||||
| CVE-2023-6408 | 1 Schneider-electric | 90 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 87 more | 2025-01-23 | N/A | 8.1 HIGH | 
| CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. | |||||