Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 768 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2022-32528 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 8.6 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32527 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32526 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted setting value messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32525 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32524 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted time reduced data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32523 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted online data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32522 1 Schneider-electric 1 Interactive Graphical Scada System 2026-06-17 N/A 9.8 CRITICAL
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted mathematically reduced data request messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
CVE-2022-32521 1 Schneider-electric 1 Data Center Expert 2026-06-17 N/A 7.1 HIGH
A CWE 502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32520 1 Schneider-electric 1 Data Center Expert 2026-06-17 N/A 8.0 HIGH
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32518. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32519 1 Schneider-electric 1 Data Center Expert 2026-06-17 N/A 8.0 HIGH
A CWE-257: Storing Passwords in a Recoverable Format vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32518 1 Schneider-electric 1 Data Center Expert 2026-06-17 N/A 8.0 HIGH
A CWE-522: Insufficiently Protected Credentials vulnerability exists that could result in unwanted access to a DCE instance when performed over a network by a malicious third-party. This CVE is unique from CVE-2022-32520. Affected Products: Data Center Expert (Versions prior to V7.9.0)
CVE-2022-32517 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2026-06-17 N/A 6.5 MEDIUM
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to render within frames on external addresses. Affected Products: Conext™ ComBox (All Versions)
CVE-2022-32516 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2026-06-17 N/A 7.5 HIGH
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could cause system’s configurations override and cause a reboot loop when the product suffers from POST-Based Cross-Site Request Forgery (CSRF). Affected Products: Conext™ ComBox (All Versions)
CVE-2022-32515 1 Schneider-electric 2 Conext Combox, Conext Combox Firmware 2026-06-17 N/A 8.6 HIGH
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)
CVE-2022-32514 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-32513 1 Schneider-electric 12 5500ac2, 5500ac2 Firmware, 5500nac and 9 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
CVE-2022-32512 1 Schneider-electric 1 Canbrass 2026-06-17 N/A 5.3 MEDIUM
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause remote code execution when a command which exploits this vulnerability is utilized. Affected Products: CanBRASS (Versions prior to V7.5.1)
CVE-2022-30238 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2026-06-17 7.5 HIGH 8.3 HIGH
A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to take over the admin account when an attacker hijacks a session. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30237 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2026-06-17 5.0 MEDIUM 8.2 HIGH
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
CVE-2022-30236 1 Schneider-electric 4 Wiser Smart Eer21000, Wiser Smart Eer21000 Firmware, Wiser Smart Eer21001 and 1 more 2026-06-17 6.4 MEDIUM 8.2 HIGH
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could allow unauthorized access when an attacker uses cross-domain attacks. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)