Filtered by vendor Aveva
Subscribe
Total
67 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-61937 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 10.0 CRITICAL |
| The vulnerability, if exploited, could allow an unauthenticated miscreant to achieve remote code execution under OS system privileges of “taoimr” service, potentially resulting in complete compromise of the model application server. | |||||
| CVE-2025-61943 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 8.4 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Standard User) to tamper with queries in Captive Historian and achieve code execution under SQL Server administrative privileges, potentially resulting in complete compromise of the SQL Server. | |||||
| CVE-2025-64691 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 8.8 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (OS standard user) to tamper with TCL Macro scripts and escalate privileges to OS system, potentially resulting in complete compromise of the model application server. | |||||
| CVE-2025-64729 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 8.1 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to tamper with Process Optimization project files, embed code, and escalate their privileges to the identity of a victim user who subsequently interacts with the project files. | |||||
| CVE-2025-65117 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 7.4 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (Process Optimization Designer User) to embed OLE objects into graphics, and escalate their privileges to the identity of a victim user who subsequently interacts with the graphical elements. | |||||
| CVE-2025-65118 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 8.8 HIGH |
| The vulnerability, if exploited, could allow an authenticated miscreant (OS Standard User) to trick Process Optimization services into loading arbitrary code and escalate privileges to OS System, potentially resulting in complete compromise of the Model Application Server. | |||||
| CVE-2025-64769 | 1 Aveva | 1 Process Optimization | 2026-01-22 | N/A | 7.1 HIGH |
| The Process Optimization application suite leverages connection channels/protocols that by-default are not encrypted and could become subject to hijacking or data leakage in certain man-in-the-middle or passive inspection scenarios. | |||||
| CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | 6.4 MEDIUM | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | |||||
| CVE-2014-5412 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | 6.4 MEDIUM | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account. | |||||
| CVE-2014-5411 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | 4.9 MEDIUM | N/A |
| Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors. | |||||
| CVE-2014-0779 | 1 Aveva | 1 Clearscada | 2025-09-24 | 6.8 MEDIUM | N/A |
| The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file). | |||||
| CVE-2017-5156 | 1 Aveva | 1 Wonderware Intouch Access Anywhere | 2025-04-20 | 6.8 MEDIUM | 8.8 HIGH |
| A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The client request may be forged from a different site. This will allow an external site to access internal RDP systems on behalf of the currently logged in user. | |||||
| CVE-2017-9962 | 1 Aveva | 1 Clearscada | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be sent to ClearSCADA client applications to cause unexpected behavior. Client applications affected include ViewX and the Server Icon. | |||||
| CVE-2017-5160 | 1 Aveva | 1 Wonderware Intouch Access Anywhere | 2025-04-20 | 3.5 LOW | 5.3 MEDIUM |
| An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly. | |||||
| CVE-2017-5158 | 1 Aveva | 1 Wonderware Intouch Access Anywhere | 2025-04-20 | 5.0 MEDIUM | 9.8 CRITICAL |
| An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified. | |||||
| CVE-2021-38410 | 1 Aveva | 7 Batch Management, Enterprise Data Management, Manufacturing Execution System and 4 more | 2025-04-17 | N/A | 7.3 HIGH |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. | |||||
| CVE-2015-0998 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 3.3 LOW | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network. | |||||
| CVE-2015-0999 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 2.1 LOW | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file. | |||||
| CVE-2015-0996 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 2.1 LOW | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password. | |||||
| CVE-2015-0997 | 2 Aveva, Schneider-electric | 2 Aveva Edge, Wonderware Intouch 2014 | 2025-04-12 | 5.0 MEDIUM | N/A |
| Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack. | |||||