Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 768 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2015-7921 1 Schneider-electric 4 Proface Gp-pro Ex Ex-ed, Proface Gp-pro Ex Pfxexedls, Proface Gp-pro Ex Pfxexedv and 1 more 2026-06-17 6.4 MEDIUM 9.1 CRITICAL
The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials.
CVE-2015-7918 1 Schneider-electric 1 Proclima 2026-06-17 6.8 MEDIUM N/A
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
CVE-2015-6485 1 Schneider-electric 8 Sage 1410, Sage 1430, Sage 1450 and 5 more 2026-06-17 5.0 MEDIUM 5.3 MEDIUM
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
CVE-2015-6462 1 Schneider-electric 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more 2026-06-17 3.5 LOW 5.4 MEDIUM
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser.
CVE-2015-6461 1 Schneider-electric 22 Bmxnoc0401, Bmxnoc0401 Firmware, Bmxnoe0100 and 19 more 2026-06-17 5.5 MEDIUM 5.4 MEDIUM
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page.
CVE-2015-3977 1 Schneider-electric 1 Imt25 Magnetic Flow Dtm 2026-06-17 7.7 HIGH N/A
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.
CVE-2015-3963 2 Schneider-electric, Windriver 14 Sage 1210, Sage 1230, Sage 1250 and 11 more 2026-06-17 5.8 MEDIUM N/A
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
CVE-2015-3962 1 Schneider-electric 1 Struxureware Building Expert Multi-purpose Management 2026-06-17 5.0 MEDIUM N/A
Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.
CVE-2015-3940 1 Schneider-electric 1 Wonderware System Platform 2014 2026-06-17 6.9 MEDIUM N/A
Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.
CVE-2015-1014 1 Schneider-electric 3 Citectscada, Opc Factory Server, Scada Expert Vijeo Citect 2026-06-17 4.4 MEDIUM 7.3 HIGH
A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.
CVE-2015-0999 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2026-06-17 2.1 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.
CVE-2015-0998 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2026-06-17 3.3 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.
CVE-2015-0997 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2026-06-17 5.0 MEDIUM N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack.
CVE-2015-0996 2 Aveva, Schneider-electric 2 Aveva Edge, Wonderware Intouch 2014 2026-06-17 2.1 LOW N/A
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password.
CVE-2015-0982 1 Schneider-electric 1 Pelco Ds-nv 2026-06-17 7.5 HIGH N/A
Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2014-9206 1 Schneider-electric 1 Device Type Manager 2026-06-17 6.9 MEDIUM N/A
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.
CVE-2014-9200 1 Schneider-electric 4 Somachine, Somove, Somove Lite and 1 more 2026-06-17 7.5 HIGH N/A
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
CVE-2014-9198 1 Schneider-electric 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more 2026-06-17 10.0 HIGH N/A
The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.
CVE-2014-9197 1 Schneider-electric 5 Etg3000 Factorycast Hmi Gateway Firmware, Tsxetg3000, Tsxetg3010 and 2 more 2026-06-17 10.0 HIGH N/A
The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.
CVE-2014-9190 1 Schneider-electric 1 Wonderware Intouch Access Anywhere Server 2026-06-17 10.0 HIGH N/A
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.