Vulnerabilities (CVE)

Filtered by CWE-326
Total 383 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-33283 1 Marvalglobal 1 Msm 2025-01-07 N/A 5.5 MEDIUM
Marval MSM through 14.19.0.12476 uses a static encryption key for secrets. An attacker that gains access to encrypted secrets can decrypt them by using this key.
CVE-2023-32414 1 Apple 1 Macos 2024-12-05 N/A 8.6 HIGH
The issue was addressed with improved checks. This issue is fixed in macOS Ventura 13.4. An app may be able to break out of its sandbox.
CVE-2024-38277 2024-12-04 N/A 5.4 MEDIUM
A unique key should be generated for a user's QR login key and their auto-login key, so the same key cannot be used interchangeably between the two.
CVE-2024-33662 2024-12-04 N/A 7.5 HIGH
Portainer before 2.20.2 improperly uses an encryption algorithm in the AesEncrypt function.
CVE-2023-37301 1 Mediawiki 1 Mediawiki 2024-11-27 N/A 5.3 MEDIUM
An issue was discovered in SubmitEntityAction in Wikibase in MediaWiki through 1.39.3. Because it doesn't use EditEntity for undo and restore, the intended interaction with AbuseFilter does not occur.
CVE-2020-3549 1 Cisco 2 Firepower Threat Defense, Secure Firewall Management Center 2024-11-26 6.8 MEDIUM 8.1 HIGH
A vulnerability in the sftunnel functionality of Cisco Firepower Management Center (FMC) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to obtain the device registration hash. The vulnerability is due to insufficient sftunnel negotiation protection during initial device registration. An attacker in a man-in-the-middle position could exploit this vulnerability by intercepting a specific flow of the sftunnel communication between an FMC device and an FTD device. A successful exploit could allow the attacker to decrypt and modify the sftunnel communication between FMC and FTD devices, allowing the attacker to modify configuration data sent from an FMC device to an FTD device or alert data sent from an FTD device to an FMC device.
CVE-2024-45719 2024-11-22 N/A 2.6 LOW
Inadequate Encryption Strength vulnerability in Apache Answer. This issue affects Apache Answer: through 1.4.0. The ids generated using the UUID v1 version are to some extent not secure enough. It can cause the generated token to be predictable. Users are recommended to upgrade to version 1.4.1, which fixes the issue.
CVE-2024-45273 2 Helmholz, Mbconnectline 27 Myrex24 V2 Virtual Server, Rex 100, Rex 100 Firmware and 24 more 2024-11-21 N/A 8.4 HIGH
An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
CVE-2024-40761 2024-11-21 N/A 5.3 MEDIUM
Inadequate Encryption Strength vulnerability in Apache Answer. This issue affects Apache Answer: through 1.3.5. Using the MD5 value of a user's email to access Gravatar is insecure and can lead to the leakage of user email. The official recommendation is to use SHA256 instead. Users are recommended to upgrade to version 1.4.0, which fixes the issue.
CVE-2024-39928 2024-11-21 N/A 7.5 HIGH
In Apache Linkis <= 1.5.0, a Random string security vulnerability in Spark EngineConn, random string generated by the Token when starting Py4j uses the Commons Lang's RandomStringUtils. Users are recommended to upgrade to version 1.6.0, which fixes this issue.
CVE-2024-38867 2024-11-21 N/A 5.9 MEDIUM
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.64), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.64), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.64), SIPROTEC 5 6MD89 (CP300) (All versions < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions < V9.64), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V9.64), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.65), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.65), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.65), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.65), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.65), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.65), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.65), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.65), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.65), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.65), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.65), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.65), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.65), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions < V9.64), SIPROTEC 5 7SX82 (CP150) (All versions < V9.65), SIPROTEC 5 7SX85 (CP300) (All versions < V9.65), SIPROTEC 5 7UM85 (CP300) (All versions < V9.64), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.65), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.65), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.65), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.65), SIPROTEC 5 7VE85 (CP300) (All versions < V9.64), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.65), SIPROTEC 5 7VU85 (CP300) (All versions < V9.64), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions installed on CP200 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.62 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.62), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.64). The affected devices are supporting weak ciphers on several ports (443/tcp for web, 4443/tcp for DIGSI 5 and configurable port for syslog over TLS). This could allow an unauthorized attacker in a man-in-the-middle position to decrypt any data passed over to and from those ports.
CVE-2024-34113 1 Adobe 1 Coldfusion 2024-11-21 N/A 5.5 MEDIUM
ColdFusion versions 2023u7, 2021u13 and earlier are affected by a Weak Cryptography for Passwords vulnerability that could result in a security feature bypass. This vulnerability arises due to the use of insufficiently strong cryptographic algorithms or flawed implementation that compromises the confidentiality of password data. An attacker could exploit this weakness to decrypt or guess passwords, potentially gaining unauthorized access to protected resources. Exploitation of this issue does not require user interaction.
CVE-2024-30119 2024-11-21 N/A 3.7 LOW
HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header.  This could allow an attacker to intercept or manipulate data during redirection.
CVE-2024-28755 2024-11-21 N/A 6.5 MEDIUM
An issue was discovered in Mbed TLS 3.5.x before 3.6.0. When an SSL context was reset with the mbedtls_ssl_session_reset() API, the maximum TLS version to be negotiated was not restored to the configured one. An attacker was able to prevent an Mbed TLS server from establishing any TLS 1.3 connection, potentially resulting in a Denial of Service or forced version downgrade from TLS 1.3 to TLS 1.2.
CVE-2024-23656 1 Linuxfoundation 1 Dex 2024-11-21 N/A 7.5 HIGH
Dex is an identity service that uses OpenID Connect to drive authentication for other apps. Dex 2.37.0 serves HTTPS with insecure TLS 1.0 and TLS 1.1. `cmd/dex/serve.go` line 425 seemingly sets TLS 1.2 as minimum version, but the whole `tlsConfig` is ignored after `TLS cert reloader` was introduced in v2.37.0. Configured cipher suites are not respected either. This issue is fixed in Dex 2.38.0.
CVE-2024-23580 2024-11-21 N/A 6.5 MEDIUM
HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of One-Time Passwords (OTPs). This could allow an attacker with access to the database to recover some or all encrypted values.
CVE-2024-23579 2024-11-21 N/A 6.5 MEDIUM
HCL DRYiCE Optibot Reset Station is impacted by insecure encryption of security questions. This could allow an attacker with access to the database to recover some or all encrypted values.
CVE-2024-22894 2 Alpha-innotec, Novelan 4 Heat Pumps, Heat Pumps Firmware, Heat Pumps and 1 more 2024-11-21 N/A 6.8 MEDIUM
An issue fixed in AIT-Deutschland Alpha Innotec Heatpumps V2.88.3 or later, V3.89.0 or later, V4.81.3 or later and Novelan Heatpumps V2.88.3 or later, V3.89.0 or later, V4.81.3 or later, allows remote attackers to execute arbitrary code via the password component in the shadow file.
CVE-2024-20692 1 Microsoft 14 Windows 10 1507, Windows 10 1607, Windows 10 1809 and 11 more 2024-11-21 N/A 5.7 MEDIUM
Microsoft Local Security Authority Subsystem Service Information Disclosure Vulnerability
CVE-2023-7237 1 Lantronix 2 Xport Edge, Xport Edge Firmware 2024-11-21 N/A 5.7 MEDIUM
Lantronix XPort sends weakly encoded credentials within web request headers.