Filtered by vendor Siemens
Subscribe
Total
1913 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2015-8214 | 1 Siemens | 8 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 5 more | 2025-04-12 | 9.7 HIGH | N/A |
A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs. | |||||
CVE-2014-2732 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 5.0 MEDIUM | N/A |
Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80. | |||||
CVE-2015-1357 | 1 Siemens | 5 Ruggedcom Firmware, Ruggedcom Win5100, Ruggedcom Win5200 and 2 more | 2025-04-12 | 5.0 MEDIUM | N/A |
Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allow context-dependent attackers to discover password hashes by reading (1) files or (2) security logs. | |||||
CVE-2014-2256 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets, a different vulnerability than CVE-2014-2257. | |||||
CVE-2016-5874 | 1 Siemens | 1 Simatic Net Pc-software | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
Siemens SIMATIC NET PC-Software before 13 SP2 allows remote attackers to cause a denial of service (OPC UA service outage) via crafted TCP packets. | |||||
CVE-2015-1595 | 1 Siemens | 1 Spcanywhere | 2025-04-12 | 4.3 MEDIUM | N/A |
The Siemens SPCanywhere application for Android and iOS does not use encryption during lookups of system ID to IP address mappings, which allows man-in-the-middle attackers to discover alarm IP addresses and spoof servers by intercepting the client-server data stream. | |||||
CVE-2014-5233 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2025-04-12 | 1.9 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. | |||||
CVE-2016-1488 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-04-12 | 4.3 MEDIUM | 6.1 MEDIUM |
Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. | |||||
CVE-2015-1601 | 1 Siemens | 1 Simatic Step 7 | 2025-04-12 | 6.8 MEDIUM | N/A |
Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. | |||||
CVE-2014-4683 | 1 Siemens | 2 Simatic Pcs7, Wincc | 2025-04-12 | 4.9 MEDIUM | N/A |
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | |||||
CVE-2016-4956 | 6 Novell, Ntp, Opensuse and 3 more | 11 Suse Manager, Ntp, Leap and 8 more | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (interleaved-mode transition and time change) via a spoofed broadcast packet. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-1548. | |||||
CVE-2016-5849 | 1 Siemens | 1 Sicam Pas\/pqs | 2025-04-12 | 1.9 LOW | 2.5 LOW |
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | |||||
CVE-2014-2731 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 9.3 HIGH | N/A |
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80. | |||||
CVE-2015-5386 | 1 Siemens | 2 Sicam Mic, Sicam Mic Firmware | 2025-04-12 | 9.3 HIGH | N/A |
Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests. | |||||
CVE-2016-9158 | 1 Siemens | 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more | 2025-04-12 | 7.8 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system. | |||||
CVE-2015-2177 | 1 Siemens | 2 Simatic S7-300 Cpu, Simatic S7-300 Cpu Firmware | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus. | |||||
CVE-2015-1049 | 1 Siemens | 10 Scalance X-200 Series Firmware, Scalance X201-3p Irt Pro, Scalance X201-3pirt and 7 more | 2025-04-12 | 6.8 MEDIUM | N/A |
The web server on Siemens SCALANCE X-200IRT switches with firmware before 5.2.0 allows remote attackers to hijack sessions via unspecified vectors. | |||||
CVE-2014-2249 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 5.8 MEDIUM | N/A |
Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
CVE-2015-2823 | 1 Siemens | 6 Simatic Hmi Basic Panels Generation 1, Simatic Hmi Basic Panels Generation 2, Simatic Hmi Comfort Panels and 3 more | 2025-04-12 | 6.8 MEDIUM | N/A |
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password. | |||||
CVE-2016-7114 | 1 Siemens | 2 En100 Ethernet Module, En100 Ethernet Module Firmware | 2025-04-12 | 9.0 HIGH | 8.8 HIGH |
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful. |