Filtered by vendor Siemens
Subscribe
Total
2187 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-27539 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914) | |||||
| CVE-2025-27495 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911) | |||||
| CVE-2025-27494 | 1 Siemens | 4 Sipass Integrated Ac5102 \(acc-g2\), Sipass Integrated Ac5102 \(acc-g2\) Firmware, Sipass Integrated Acc-ap and 1 more | 2026-06-17 | N/A | 9.1 CRITICAL |
| A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges. | |||||
| CVE-2025-27493 | 1 Siemens | 4 Sipass Integrated Ac5102 \(acc-g2\), Sipass Integrated Ac5102 \(acc-g2\) Firmware, Sipass Integrated Acc-ap and 1 more | 2026-06-17 | N/A | 8.2 HIGH |
| A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges. | |||||
| CVE-2025-27438 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2025-27398 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 2.7 LOW |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths. This could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem. | |||||
| CVE-2025-27397 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 3.8 LOW |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit user controlled paths to which logs are written and from where they are read. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files in the filesystem, if and only if the malicious path ends with 'log' . | |||||
| CVE-2025-27396 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the elevation of privileges required to perform certain valid functionality. This could allow an authenticated lowly-privileged remote attacker to escalate their privileges. | |||||
| CVE-2025-27395 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the scope of files accessible through and the privileges of the SFTP functionality. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files. | |||||
| CVE-2025-27394 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new SNMP users. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device. | |||||
| CVE-2025-27393 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new users. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device. | |||||
| CVE-2025-27392 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 7.2 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new VXLAN configurations. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device. | |||||
| CVE-2025-26390 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2026-06-17 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user. | |||||
| CVE-2025-26389 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2026-06-17 | N/A | 10.0 CRITICAL |
| A vulnerability has been identified in OZW672 (All versions < V8.0), OZW772 (All versions < V8.0). The web service in affected devices does not sanitize the input parameters required for the `exportDiagramPage` endpoint. This could allow an unauthenticated remote attacker to execute arbitrary code with root privileges. | |||||
| CVE-2025-25267 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2026-06-17 | N/A | 6.2 MEDIUM |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system. | |||||
| CVE-2025-25266 | 1 Siemens | 1 Tecnomatix Plant Simulation | 2026-06-17 | N/A | 6.8 MEDIUM |
| A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict access to the file deletion functionality. This could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files. | |||||
| CVE-2025-25175 | 1 Siemens | 1 Simcenter Femap | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443) | |||||
| CVE-2025-24956 | 1 Siemens | 1 Openv2g | 2026-06-17 | N/A | 6.2 MEDIUM |
| A vulnerability has been identified in OpenV2G (All versions < V0.9.6). The OpenV2G EXI parsing feature is missing a length check when parsing X509 serial numbers. Thus, an attacker could introduce a buffer overflow that leads to memory corruption. | |||||
| CVE-2025-23402 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
| CVE-2025-23401 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. | |||||
