Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1901 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2011-4511 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510.
CVE-2013-0679 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 4.0 MEDIUM N/A
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
CVE-2012-2595 1 Siemens 1 Wincc 2025-04-11 4.3 MEDIUM N/A
Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.
CVE-2013-3927 1 Siemens 1 Comos 2025-04-11 4.6 MEDIUM N/A
Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access.
CVE-2010-2772 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2025-04-11 6.9 MEDIUM 7.8 HIGH
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
CVE-2013-4652 1 Siemens 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more 2025-04-11 10.0 HIGH N/A
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
CVE-2011-4509 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 10.0 HIGH N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
CVE-2013-6840 1 Siemens 1 Comos 2025-04-11 6.9 MEDIUM N/A
Siemens COMOS before 9.2.0.8.1, 10.0 before 10.0.3.1.40, and 10.1 before 10.1.0.0.2 allows local users to gain database privileges via unspecified vectors.
CVE-2013-4779 1 Siemens 2 Enterprise Openscape Branch, Openscape Session Border Controller 2025-04-11 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
CVE-2013-0669 1 Siemens 1 Wincc Tia Portal 2025-04-11 4.0 MEDIUM N/A
The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.
CVE-2013-4943 1 Siemens 1 Comos 2025-04-11 7.2 HIGH N/A
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access.
CVE-2013-4651 1 Siemens 17 Scalance W700 Series Firmware, Scalance W744-1, Scalance W744-1pro and 14 more 2025-04-11 6.6 MEDIUM N/A
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
CVE-2013-0672 1 Siemens 1 Wincc Tia Portal 2025-04-11 3.5 LOW N/A
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.
CVE-2013-4912 1 Siemens 1 Wincc 2025-04-11 5.8 MEDIUM N/A
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
CVE-2012-3030 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 5.0 MEDIUM N/A
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
CVE-2011-4529 1 Siemens 1 Automation License Manager 2025-04-11 7.5 HIGH N/A
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
CVE-2013-3959 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 4.0 MEDIUM N/A
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.
CVE-2012-3016 1 Siemens 6 Simatic S7-400 Cpu 412-2 Pn, Simatic S7-400 Cpu 414-3 Pn\/dp, Simatic S7-400 Cpu 414f-3 Pn\/dp and 3 more 2025-04-11 7.8 HIGH N/A
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
CVE-2011-3321 1 Siemens 2 Simatic Wincc Flexible Runtime, Simatic Wincc Runtime 2025-04-11 9.3 HIGH N/A
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
CVE-2013-3634 1 Siemens 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more 2025-04-11 7.5 HIGH N/A
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.