Filtered by vendor Siemens
Subscribe
Total
2154 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2021-4160 | 4 Debian, Openssl, Oracle and 1 more | 8 Debian Linux, Openssl, Enterprise Manager Ops Center and 5 more | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
| There is a carry propagation bug in the MIPS32 and MIPS64 squaring procedure. Many EC algorithms are affected, including some of the TLS 1.3 default curves. Impact was not analyzed in detail, because the pre-requisites for attack are considered unlikely and include reusing private keys. Analysis suggests that attacks against RSA and DSA as a result of this defect would be very difficult to perform and are not believed likely. Attacks against DH are considered just feasible (although very difficult) because most of the work necessary to deduce information about a private key may be performed offline. The amount of resources required for such an attack would be significant. However, for an attack on TLS to be meaningful, the server would have to share the DH private key among multiple clients, which is no longer an option since CVE-2016-0701. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0.0. It was addressed in the releases of 1.1.1m and 3.0.1 on the 15th of December 2021. For the 1.0.2 release it is addressed in git commit 6fc1aaaf3 that is available to premium support customers only. It will be made available in 1.0.2zc when it is released. The issue only affects OpenSSL on MIPS platforms. Fixed in OpenSSL 3.0.1 (Affected 3.0.0). Fixed in OpenSSL 1.1.1m (Affected 1.1.1-1.1.1l). Fixed in OpenSSL 1.0.2zc-dev (Affected 1.0.2-1.0.2zb). | |||||
| CVE-2021-46699 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains a stack based buffer overflow vulnerability while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15061) | |||||
| CVE-2021-46162 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15048) | |||||
| CVE-2021-46161 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15302) | |||||
| CVE-2021-46160 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15286) | |||||
| CVE-2021-46159 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15050) | |||||
| CVE-2021-46158 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15085, ZDI-CAN-15289, ZDI-CAN-15602) | |||||
| CVE-2021-46157 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14757) | |||||
| CVE-2021-46156 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14684) | |||||
| CVE-2021-46155 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14683, ZDI-CAN-15283, ZDI-CAN-15303, ZDI-CAN-15593) | |||||
| CVE-2021-46154 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a stack based buffer overflow vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14646, ZDI-CAN-14679, ZDI-CAN-15084, ZDI-CAN-15304) | |||||
| CVE-2021-46153 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a memory corruption vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14645, ZDI-CAN-15305, ZDI-CAN-15589, ZDI-CAN-15599) | |||||
| CVE-2021-46152 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains a type confusion vulnerability while parsing NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14643, ZDI-CAN-14644, ZDI-CAN-14755, ZDI-CAN-15183) | |||||
| CVE-2021-46151 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082) | |||||
| CVE-2021-45460 | 1 Siemens | 2 Sicam Pq Analyzer, Sicam Pq Analyzer Firmware | 2024-11-21 | 5.5 MEDIUM | 8.1 HIGH |
| A vulnerability has been identified in SICAM PQ Analyzer (All versions < V3.18). A service is started by an unquoted registry entry. As there are spaces in this path, attackers with write privilege to those directories might be able to plant executables that will run in place of the legitimate process. Attackers might achieve persistence on the system ("backdoors") or cause a denial of service. | |||||
| CVE-2021-45117 | 2 Opcfoundation, Siemens | 4 Ua-nodeset, Simatic Net Pc, Sitop Manager and 1 more | 2024-11-21 | 4.3 MEDIUM | 6.5 MEDIUM |
| The OPC autogenerated ANSI C stack stubs (in the NodeSets) do not handle all error cases. This can lead to a NULL pointer dereference. | |||||
| CVE-2021-45106 | 1 Siemens | 1 Sicam Toolbox Ii | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in SICAM TOOLBOX II (All versions). Affected applications use a circumventable access control within a database service. This could allow an attacker to access the database. | |||||
| CVE-2021-45034 | 1 Siemens | 8 Cp-8000 Master Module With I\/o -25\/\+70, Cp-8000 Master Module With I\/o -25\/\+70 Firmware, Cp-8000 Master Module With I\/o -40\/\+70 and 5 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). The web server of the affected system allows access to logfiles and diagnostic data generated by a privileged user. An unauthenticated attacker could access the files by knowing the corresponding download links. | |||||
| CVE-2021-45033 | 1 Siemens | 8 Cp-8000 Master Module With I\/o -25\/\+70, Cp-8000 Master Module With I\/o -25\/\+70 Firmware, Cp-8000 Master Module With I\/o -40\/\+70 and 5 more | 2024-11-21 | 8.5 HIGH | 8.8 HIGH |
| A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device. | |||||
| CVE-2021-44695 | 1 Siemens | 192 Simatic Et 200 Sp Open Controller Cpu 1515sp Pc, Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware, Simatic S7-1200 Cpu 1211c and 189 more | 2024-11-21 | N/A | 4.9 MEDIUM |