Filtered by vendor Siemens
Subscribe
Total
1901 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-25677 | 1 Siemens | 6 Nucleus Net, Nucleus Readystart V3, Nucleus Readystart V4 and 3 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving. | |||||
CVE-2021-25676 | 1 Siemens | 8 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 5 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically. | |||||
CVE-2021-25675 | 1 Siemens | 1 Simatic S7-plcsim | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a divide by zero operation could occur and cause the application to terminate unexpectedly and must be restarted to restore the service. | |||||
CVE-2021-25674 | 1 Siemens | 1 Simatic S7-plcsim | 2024-11-21 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, a NULL pointer deference condition could cause the application to terminate unexpectedly and must be restarted to restore the service. | |||||
CVE-2021-25673 | 1 Siemens | 1 Simatic S7-plcsim | 2024-11-21 | 4.9 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in SIMATIC S7-PLCSIM V5.4 (All versions). An attacker with local access to the system could cause a Denial-of-Service condition in the application when it is used to open a specially crafted file. As a consequence, the application could enter an infinite loop, become unresponsive and must be restarted to restore the service. | |||||
CVE-2021-25671 | 1 Siemens | 6 Rwg1.m12, Rwg1.m12 Firmware, Rwg1.m12d and 3 more | 2024-11-21 | 3.3 LOW | 4.3 MEDIUM |
A vulnerability has been identified in RWG1.M12 (All versions < V1.16.16), RWG1.M12D (All versions < V1.16.16), RWG1.M8 (All versions < V1.16.16). Sending specially crafted ARP packets to an affected device could cause a partial denial-of-service, preventing the device to operate normally. A restart is needed to restore normal operations. | |||||
CVE-2021-25670 | 1 Siemens | 1 Tecnomatix Robotexpert | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Tecnomatix RobotExpert (All versions < V16.1). Affected applications lack proper validation of user-supplied data when parsing CELL files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12608) | |||||
CVE-2021-25669 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the web server may write out of bounds in stack. An attacker might leverage this to denial-of-service of the device or remote code execution. | |||||
CVE-2021-25668 | 1 Siemens | 58 Scalance X200-4p Irt, Scalance X200-4p Irt Firmware, Scalance X201-3p Irt and 55 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT (All versions < 5.5.1), SCALANCE X201-3P IRT PRO (All versions < 5.5.1), SCALANCE X202-2 IRT (All versions < 5.5.1), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All versions < 5.5.1), SCALANCE X202-2P IRT PRO (All versions < 5.5.1), SCALANCE X204 IRT (All versions < 5.5.1), SCALANCE X204 IRT PRO (All versions < 5.5.1), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < 5.5.1), SCALANCE XF202-2P IRT (All versions < 5.5.1), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204 IRT (All versions < 5.5.1), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < 5.5.1), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5). Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code. | |||||
CVE-2021-25667 | 1 Siemens | 30 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M-800 and 27 more | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. | |||||
CVE-2021-25666 | 1 Siemens | 4 Scalance W740, Scalance W740 Firmware, Scalance W780 and 1 more | 2024-11-21 | 3.3 LOW | 4.3 MEDIUM |
A vulnerability has been identified in SCALANCE W780 and W740 (IEEE 802.11n) family (All versions < V6.3). Sending specially crafted packets through the ARP protocol to an affected device could cause a partial denial-of-service, preventing the device to operate normally for a short period of time. | |||||
CVE-2021-25665 | 1 Siemens | 1 Simcenter Star-ccm\+ | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700) | |||||
CVE-2021-25662 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition. | |||||
CVE-2021-25661 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. | |||||
CVE-2021-25660 | 1 Siemens | 19 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 16 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. | |||||
CVE-2021-25659 | 1 Siemens | 1 Automation License Manager | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system. | |||||
CVE-2021-25220 | 5 Fedoraproject, Isc, Juniper and 2 more | 48 Fedora, Bind, Junos and 45 more | 2024-11-21 | 4.0 MEDIUM | 6.8 MEDIUM |
BIND 9.11.0 -> 9.11.36 9.12.0 -> 9.16.26 9.17.0 -> 9.18.0 BIND Supported Preview Editions: 9.11.4-S1 -> 9.11.36-S1 9.16.8-S1 -> 9.16.26-S1 Versions of BIND 9 earlier than those shown - back to 9.1.0, including Supported Preview Editions - are also believed to be affected but have not been tested as they are EOL. The cache could become poisoned with incorrect records leading to queries being made to the wrong servers, which might also result in false information being returned to clients. | |||||
CVE-2021-25219 | 6 Debian, Fedoraproject, Isc and 3 more | 23 Debian Linux, Fedora, Bind and 20 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
In BIND 9.3.0 -> 9.11.35, 9.12.0 -> 9.16.21, and versions 9.9.3-S1 -> 9.11.35-S1 and 9.16.8-S1 -> 9.16.21-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.18 of the BIND 9.17 development branch, exploitation of broken authoritative servers using a flaw in response processing can cause degradation in BIND resolver performance. The way the lame cache is currently designed makes it possible for its internal data structures to grow almost infinitely, which may cause significant delays in client query processing. | |||||
CVE-2021-25217 | 5 Debian, Fedoraproject, Isc and 2 more | 26 Debian Linux, Fedora, Dhcp and 23 more | 2024-11-21 | 3.3 LOW | 7.4 HIGH |
In ISC DHCP 4.1-ESV-R1 -> 4.1-ESV-R16, ISC DHCP 4.4.0 -> 4.4.2 (Other branches of ISC DHCP (i.e., releases in the 4.0.x series or lower and releases in the 4.3.x series) are beyond their End-of-Life (EOL) and no longer supported by ISC. From inspection it is clear that the defect is also present in releases from those series, but they have not been officially tested for the vulnerability), The outcome of encountering the defect while reading a lease that will trigger it varies, according to: the component being affected (i.e., dhclient or dhcpd) whether the package was built as a 32-bit or 64-bit binary whether the compiler flag -fstack-protection-strong was used when compiling In dhclient, ISC has not successfully reproduced the error on a 64-bit system. However, on a 32-bit system it is possible to cause dhclient to crash when reading an improper lease, which could cause network connectivity problems for an affected system due to the absence of a running DHCP client process. In dhcpd, when run in DHCPv4 or DHCPv6 mode: if the dhcpd server binary was built for a 32-bit architecture AND the -fstack-protection-strong flag was specified to the compiler, dhcpd may exit while parsing a lease file containing an objectionable lease, resulting in lack of service to clients. Additionally, the offending lease and the lease immediately following it in the lease database may be improperly deleted. if the dhcpd server binary was built for a 64-bit architecture OR if the -fstack-protection-strong compiler flag was NOT specified, the crash will not occur, but it is possible for the offending lease and the lease which immediately followed it to be improperly deleted. | |||||
CVE-2021-25216 | 4 Debian, Isc, Netapp and 1 more | 23 Debian Linux, Bind, Active Iq Unified Manager and 20 more | 2024-11-21 | 6.8 MEDIUM | 8.1 HIGH |
In BIND 9.5.0 -> 9.11.29, 9.12.0 -> 9.16.13, and versions BIND 9.11.3-S1 -> 9.11.29-S1 and 9.16.8-S1 -> 9.16.13-S1 of BIND Supported Preview Edition, as well as release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch, BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting values for the tkey-gssapi-keytab or tkey-gssapi-credential configuration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. For servers that meet these conditions, the ISC SPNEGO implementation is vulnerable to various attacks, depending on the CPU architecture for which BIND was built: For named binaries compiled for 64-bit platforms, this flaw can be used to trigger a buffer over-read, leading to a server crash. For named binaries compiled for 32-bit platforms, this flaw can be used to trigger a server crash due to a buffer overflow and possibly also to achieve remote code execution. We have determined that standard SPNEGO implementations are available in the MIT and Heimdal Kerberos libraries, which support a broad range of operating systems, rendering the ISC implementation unnecessary and obsolete. Therefore, to reduce the attack surface for BIND users, we will be removing the ISC SPNEGO implementation in the April releases of BIND 9.11 and 9.16 (it had already been dropped from BIND 9.17). We would not normally remove something from a stable ESV (Extended Support Version) of BIND, but since system libraries can replace the ISC SPNEGO implementation, we have made an exception in this case for reasons of stability and security. |