Filtered by vendor Tenda
Subscribe
Total
1168 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2022-37807 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState. | |||||
CVE-2022-37806 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient. | |||||
CVE-2022-37805 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromWizardHandle. | |||||
CVE-2022-37804 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter in the function saveParentControlInfo. | |||||
CVE-2022-37803 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromAddressNat. | |||||
CVE-2022-37802 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting. | |||||
CVE-2022-37801 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand. | |||||
CVE-2022-37800 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function fromSetRouteStatic. | |||||
CVE-2022-37799 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter at the function setSmartPowerManagement. | |||||
CVE-2022-37798 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetVirtualSer. | |||||
CVE-2022-37292 | 1 Tenda | 2 Ax12, Ax12 Firmware | 2024-11-21 | N/A | 5.5 MEDIUM |
Tenda AX12 V22.03.01.21_CN is vulnerable to Buffer Overflow. This overflow is triggered in the sub_42FDE4 function, which satisfies the request of the upper-level interface function sub_430124, that is, handles the post request under /goform/SetIpMacBind. | |||||
CVE-2022-37175 | 1 Tenda | 2 Ac15, Ac15 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet. | |||||
CVE-2022-36587 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by sprintf in function in the httpd binary. | |||||
CVE-2022-36586 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by strcpy in function 0x869f4 in the httpd binary. | |||||
CVE-2022-36585 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, in httpd binary, the addDhcpRule function has a buffer overflow caused by sscanf. | |||||
CVE-2022-36584 | 1 Tenda | 2 G3, G3 Firmware | 2024-11-21 | N/A | 9.8 CRITICAL |
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, the getsinglepppuser function has a buffer overflow caused by sscanf. | |||||
CVE-2022-36571 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 7.2 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the mask parameter at /goform/WanParameterSetting. | |||||
CVE-2022-36570 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 7.2 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the time parameter at /goform/SetLEDCfg. | |||||
CVE-2022-36569 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the deviceList parameter at /goform/setMacFilterCfg. | |||||
CVE-2022-36568 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2024-11-21 | N/A | 8.8 HIGH |
Tenda AC9 V15.03.05.19 was discovered to contain a stack overflow via the list parameter at /goform/setPptpUserList. |