Vulnerabilities (CVE)

Filtered by vendor Tenda Subscribe
Total 1846 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-33835 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
CVE-2024-33365 1 Tenda 2 Ac10, Ac10 Firmware 2026-06-17 N/A 7.5 HIGH
Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacker to execute arbitrary code via the Virtual_Data_Check function in the bin/httpd component.
CVE-2024-33217 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter in ip/goform/addressNat.
CVE-2024-33215 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat.
CVE-2024-33214 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the entrys parameter in ip/goform/RouteStatic.
CVE-2024-33213 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 6.5 MEDIUM
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic.
CVE-2024-33212 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 8.8 HIGH
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm.
CVE-2024-33211 1 Tenda 2 Fh1206, Fh1206 Firmware 2026-06-17 N/A 7.3 HIGH
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter in ip/goform/QuickIndex.
CVE-2024-33181 1 Tenda 2 Ac18, Ac18 Firmware 2026-06-17 N/A 8.8 HIGH
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceMac parameter at ip/goform/addWifiMacFilter.
CVE-2024-32320 1 Tenda 2 Ac500, Ac500 Firmware 2026-06-17 N/A 5.9 MEDIUM
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
CVE-2024-32318 1 Tenda 2 Ac500, Ac500 Firmware 2026-06-17 N/A 9.8 CRITICAL
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
CVE-2024-32317 1 Tenda 2 Ac10, Ac10 Firmware 2026-06-17 N/A 7.5 HIGH
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32316 1 Tenda 2 Ac500, Ac500 Firmware 2026-06-17 N/A 6.5 MEDIUM
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
CVE-2024-32315 1 Tenda 2 Fh1202, Fh1202 Firmware 2026-06-17 N/A 4.7 MEDIUM
Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32314 1 Tenda 2 Ac500, Ac500 Firmware 2026-06-17 N/A 3.8 LOW
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
CVE-2024-32313 1 Tenda 2 Fh1205, Fh1205 Firmware 2026-06-17 N/A 6.5 MEDIUM
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32312 1 Tenda 2 F1203, F1203 Firmware 2026-06-17 N/A 5.7 MEDIUM
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.
CVE-2024-32311 1 Tenda 2 Fh1203, Fh1203 Firmware 2026-06-17 N/A 6.5 MEDIUM
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
CVE-2024-32310 1 Tenda 2 F1203, F1203 Firmware 2026-06-17 N/A 8.0 HIGH
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.
CVE-2024-32307 1 Tenda 2 Fh1205, Fh1205 Firmware 2026-06-17 N/A 7.4 HIGH
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.