CVE-2024-3909

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md Broken Link
https://vuldb.com/?ctiid.261145 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261145 Third Party Advisory VDB Entry
https://vuldb.com/?submit.313804 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md Broken Link
https://vuldb.com/?ctiid.261145 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261145 Third Party Advisory VDB Entry
https://vuldb.com/?submit.313804 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\(1307\):*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*

History

07 Feb 2025, 01:57

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md - Broken Link
References () https://vuldb.com/?ctiid.261145 - () https://vuldb.com/?ctiid.261145 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.261145 - () https://vuldb.com/?id.261145 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.313804 - () https://vuldb.com/?submit.313804 - Third Party Advisory, VDB Entry
First Time Tenda
Tenda ac500 Firmware
Tenda ac500
CPE cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\(1307\):*:*:*:*:*:*:*
CWE CWE-787

21 Nov 2024, 09:30

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md -
References () https://vuldb.com/?ctiid.261145 - () https://vuldb.com/?ctiid.261145 -
References () https://vuldb.com/?id.261145 - () https://vuldb.com/?id.261145 -
References () https://vuldb.com/?submit.313804 - () https://vuldb.com/?submit.313804 -

14 May 2024, 15:42

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad fue encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como crítica. La función formexeCommand del archivo /goform/execCommand es afectada por esta vulnerabilidad. La manipulación del argumento cmdinput provoca un desbordamiento de búfer en la región stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. A esta vulnerabilidad se le asignó el identificador VDB-261145. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

17 Apr 2024, 12:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-04-17 12:15

Updated : 2025-02-07 01:57


NVD link : CVE-2024-3909

Mitre link : CVE-2024-3909

CVE.ORG link : CVE-2024-3909


JSON object : View

Products Affected

tenda

  • ac500
  • ac500_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write