| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-26390 | 1 Siemens | 4 Ozw672, Ozw672 Firmware, Ozw772 and 1 more | 2025-10-03 | N/A | 9.8 CRITICAL |
| A vulnerability has been identified in OZW672 (All versions < V6.0), OZW772 (All versions < V6.0). The web service of affected devices is vulnerable to SQL injection when checking authentication data. This could allow an unauthenticated remote attacker to bypass the check and authenticate as Administrator user. | |||||
| CVE-2024-33577 | 1 Siemens | 2 Simcenter Femap, Simcenter Nastran | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-31980 | 1 Siemens | 1 Parasolid | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.210), Parasolid V36.1 (All versions < V36.1.185). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted X_T part file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-23468) | |||||
| CVE-2024-32635 | 1 Siemens | 3 Jt2go, Parasolid, Teamcenter Visualization | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-32636 | 1 Siemens | 3 Jt2go, Parasolid, Teamcenter Visualization | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-32637 | 1 Siemens | 3 Jt2go, Parasolid, Teamcenter Visualization | 2025-10-03 | N/A | 3.3 LOW |
| A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. | |||||
| CVE-2024-26276 | 1 Siemens | 3 Jt2go, Parasolid, Teamcenter Visualization | 2025-10-03 | N/A | 3.3 LOW |
| A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition. | |||||
| CVE-2024-26275 | 1 Siemens | 3 Jt2go, Parasolid, Teamcenter Visualization | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-34086 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted CGM file. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2024-34085 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2025-10-03 | N/A | 7.8 HIGH |
| A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process. | |||||
| CVE-2025-30176 | 1 Siemens | 5 Simatic Pcs Neo, Sinec Nms, Sinema Remote Connect and 2 more | 2025-10-03 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | |||||
| CVE-2025-30175 | 1 Siemens | 5 Simatic Pcs Neo, Sinec Nms, Sinema Remote Connect and 2 more | 2025-10-03 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | |||||
| CVE-2025-30174 | 1 Siemens | 4 Sinec Nms, Sinema Remote Connect, Totally Integrated Automation Portal and 1 more | 2025-10-03 | N/A | 7.5 HIGH |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound read buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition. | |||||
| CVE-2025-40802 | 1 Siemens | 2 Ruggedcom Rst2428p, Ruggedcom Rst2428p Firmware | 2025-10-03 | N/A | 3.1 LOW |
| A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device may be susceptible to resource exhaustion when subjected to high volumes of query requests. This could allow an attacker to cause a temporary denial of service, with the system recovering once the activity stops. | |||||
| CVE-2025-40803 | 1 Siemens | 2 Ruggedcom Rst2428p, Ruggedcom Rst2428p Firmware | 2025-10-03 | N/A | 3.1 LOW |
| A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device exposes certain non-critical information from the device. This could allow an unauthenticated attacker to access sensitive data, potentially leading to a breach of confidentiality. | |||||
| CVE-2024-45385 | 1 Siemens | 1 Industrial Edge Management | 2025-10-03 | N/A | 4.7 MEDIUM |
| A vulnerability has been identified in Industrial Edge Management OS (IEM-OS) (All versions). Affected components are vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link. | |||||
| CVE-2024-36266 | 1 Siemens | 1 Powersys | 2025-09-26 | N/A | 9.3 CRITICAL |
| A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. | |||||
| CVE-2024-53977 | 1 Siemens | 2 Modelsim, Questa | 2025-09-25 | N/A | 6.7 MEDIUM |
| A vulnerability has been identified in ModelSim (All versions < V2025.1), Questa (All versions < V2025.1). An example setup script contained in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch the script from a user-writable directory. | |||||
| CVE-2024-53041 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2025-09-24 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000) | |||||
| CVE-2024-53242 | 1 Siemens | 2 Teamcenter Visualization, Tecnomatix Plant Simulation | 2025-09-24 | N/A | 7.8 HIGH |
| A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206) | |||||