| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2025-40578 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions). Affected devices do not properly handle multiple incoming Profinet packets received in rapid succession. An unauthenticated remote attacker can exploit this flaw by sending multiple packets in a very short time frame, which leads to a crash of the dcpd process. | |||||
| CVE-2025-40577 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process. | |||||
| CVE-2025-40576 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process. | |||||
| CVE-2025-40575 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 4.3 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly validate incoming Profinet packets. An unauthenticated remote attacker can exploit this flaw by sending a specially crafted malicious packet, which leads to a crash of the dcpd process. | |||||
| CVE-2025-40574 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 7.8 HIGH |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to interact with the backupmanager service. | |||||
| CVE-2025-40573 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 4.4 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices are vulnerable to path traversal attacks. This could allow a privileged local attacker to restore backups that are outside the backup folder. | |||||
| CVE-2025-40572 | 1 Siemens | 2 Scalance Lpe9403, Scalance Lpe9403 Firmware | 2026-06-17 | N/A | 5.5 MEDIUM |
| A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0 HF0). Affected devices do not properly assign permissions to critical ressources. This could allow a non-privileged local attacker to access sensitive information stored on the device. | |||||
| CVE-2025-40566 | 1 Siemens | 1 Simatic Pcs Neo | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. | |||||
| CVE-2025-38502 | 3 Debian, Linux, Siemens | 4 Debian Linux, Linux Kernel, Simatic Cn 4100 and 1 more | 2026-06-17 | N/A | 7.1 HIGH |
| In the Linux kernel, the following vulnerability has been resolved: bpf: Fix oob access in cgroup local storage Lonial reported that an out-of-bounds access in cgroup local storage can be crafted via tail calls. Given two programs each utilizing a cgroup local storage with a different value size, and one program doing a tail call into the other. The verifier will validate each of the indivial programs just fine. However, in the runtime context the bpf_cg_run_ctx holds an bpf_prog_array_item which contains the BPF program as well as any cgroup local storage flavor the program uses. Helpers such as bpf_get_local_storage() pick this up from the runtime context: ctx = container_of(current->bpf_ctx, struct bpf_cg_run_ctx, run_ctx); storage = ctx->prog_item->cgroup_storage[stype]; if (stype == BPF_CGROUP_STORAGE_SHARED) ptr = &READ_ONCE(storage->buf)->data[0]; else ptr = this_cpu_ptr(storage->percpu_buf); For the second program which was called from the originally attached one, this means bpf_get_local_storage() will pick up the former program's map, not its own. With mismatching sizes, this can result in an unintended out-of-bounds access. To fix this issue, we need to extend bpf_map_owner with an array of storage_cookie[] to match on i) the exact maps from the original program if the second program was using bpf_get_local_storage(), or ii) allow the tail call combination if the second program was not using any of the cgroup local storage maps. | |||||
| CVE-2025-32872 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetOverview' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32871 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'MigrateDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32870 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetTraces' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32869 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32868 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ExportCertificate' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32867 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32866 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetLogs' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32865 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateLog' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32864 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32863 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||
| CVE-2025-32862 | 1 Siemens | 1 Telecontrol Server Basic | 2026-06-17 | N/A | 8.8 HIGH |
| A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockTraceLevelSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. | |||||