Filtered by vendor Siemens
Subscribe
Total
2134 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-6865 | 1 Siemens | 16 Pcs 7, Primary Setup Tool, Security Configuration Tool and 13 more | 2025-04-20 | 6.1 MEDIUM | 6.5 MEDIUM |
| A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. | |||||
| CVE-2017-2686 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 4.0 MEDIUM | 6.5 MEDIUM |
| Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information. | |||||
| CVE-2017-13099 | 3 Arubanetworks, Siemens, Wolfssl | 4 Instant, Scalance W1750d, Scalance W1750d Firmware and 1 more | 2025-04-20 | 4.3 MEDIUM | 7.5 HIGH |
| wolfSSL prior to version 3.12.2 provides a weak Bleichenbacher oracle when any TLS cipher suite using RSA key exchange is negotiated. An attacker can recover the private key from a vulnerable wolfSSL application. This vulnerability is referred to as "ROBOT." | |||||
| CVE-2016-7987 | 1 Siemens | 8 Eta2 Firmware, Eta4 Firmware, Sicam Ak and 5 more | 2025-04-20 | 7.8 HIGH | 7.5 HIGH |
| An issue was discovered in Siemens ETA4 firmware (all versions prior to Revision 08) of the SM-2558 extension module for: SICAM AK, SICAM TM 1703, SICAM BC 1703, and SICAM AK 3. Specially crafted packets sent to Port 2404/TCP could cause the affected device to go into defect mode. A cold start might be required to recover the system, a Denial-of-Service Vulnerability. | |||||
| CVE-2017-9946 | 1 Siemens | 8 Apogee Pxc, Apogee Pxc Firmware, Apogee Pxc Modular and 5 more | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device. | |||||
| CVE-2017-12735 | 1 Siemens | 2 Logo\!, Logo\! 8 Bm Firmware | 2025-04-20 | 5.8 MEDIUM | 7.4 HIGH |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. | |||||
| CVE-2015-5219 | 10 Canonical, Debian, Fedoraproject and 7 more | 20 Ubuntu Linux, Debian Linux, Fedora and 17 more | 2025-04-20 | 5.0 MEDIUM | 7.5 HIGH |
| The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a crafted NTP packet. | |||||
| CVE-2017-14023 | 1 Siemens | 2 Simatic Pcs7, Simatic Wincc | 2025-04-20 | 4.0 MEDIUM | 4.9 MEDIUM |
| An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. | |||||
| CVE-2017-2689 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 6.5 MEDIUM | 8.8 HIGH |
| Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. | |||||
| CVE-2017-6864 | 1 Siemens | 1 Ruggedcom Rox I | 2025-04-20 | 3.5 LOW | 5.4 MEDIUM |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow an authenticated user to perform stored Cross-Site Scripting attacks. | |||||
| CVE-2016-3949 | 1 Siemens | 4 Simatic S7-300 With Profitnet Support, Simatic S7-300 With Profitnet Support Firmware, Simatic S7-300 Without Profitnet Support and 1 more | 2025-04-12 | 7.8 HIGH | 7.5 HIGH |
| Siemens SIMATIC S7-300 Profinet-enabled CPU devices with firmware before 3.2.12 and SIMATIC S7-300 Profinet-disabled CPU devices with firmware before 3.3.12 allow remote attackers to cause a denial of service (defect-mode transition) via crafted (1) ISO-TSAP or (2) Profibus packets. | |||||
| CVE-2015-7836 | 1 Siemens | 1 Ruggedcom Rugged Operating System | 2025-04-12 | 3.3 LOW | N/A |
| Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame. | |||||
| CVE-2015-1599 | 1 Siemens | 1 Spcanywhere | 2025-04-12 | 2.1 LOW | N/A |
| The Siemens SPCanywhere application for iOS allows physically proximate attackers to bypass intended access restrictions by leveraging a filesystem architectural error. | |||||
| CVE-2016-4785 | 1 Siemens | 9 Siprotec 4 En100, Siprotec Compact Model, Siprotec Compact Model 7rw80 and 6 more | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
| A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices. | |||||
| CVE-2016-7959 | 1 Siemens | 1 Simatic Step 7 | 2025-04-12 | 1.9 LOW | 4.7 MEDIUM |
| Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack. | |||||
| CVE-2014-2259 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 7.8 HIGH | N/A |
| Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets. | |||||
| CVE-2014-2733 | 1 Siemens | 1 Sinema Server | 2025-04-12 | 5.0 MEDIUM | N/A |
| Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via crafted HTTP requests to port (1) 4999 or (2) 80. | |||||
| CVE-2014-5232 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2025-04-12 | 1.9 LOW | N/A |
| The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state. | |||||
| CVE-2016-5744 | 1 Siemens | 1 Simatic Wincc | 2025-04-12 | 5.0 MEDIUM | 7.5 HIGH |
| Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. | |||||
| CVE-2016-3155 | 1 Siemens | 1 Apogee Insight | 2025-04-12 | 3.6 LOW | 3.4 LOW |
| Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors. | |||||