CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-45469 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45468 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45467 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45466 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45465 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45464 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45463 1 Siemens 1 Tecnomatix Plant Simulation 2024-12-10 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-30757 1 Siemens 1 Totally Integrated Automation Portal 2024-12-10 N/A 6.2 MEDIUM
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions). The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.
CVE-2020-28400 1 Siemens 157 Dk Standard Ethernet Controller Evaluation Kit, Dk Standard Ethernet Controller Evaluation Kit Firmware, Ek-ertec 200 Evaulation Kit and 154 more 2024-12-10 5.0 MEDIUM 7.5 HIGH
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
CVE-2024-39876 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 4.0 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly handle log rotation. This could allow an unauthenticated remote attacker to cause a denial of service condition through resource exhaustion on the device.
CVE-2024-39875 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows authenticated, low privilege users with the 'Manage own remote connections' permission to retrieve details about other users and group memberships.
CVE-2024-39874 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its Client Communication component. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
CVE-2024-39873 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 7.5 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly implement brute force protection against user credentials in its web API. This could allow an attacker to learn user credentials that are vulnerable to brute force attacks.
CVE-2024-39872 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 9.6 CRITICAL
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application does not properly assign rights to temporary files created during its update process. This could allow an authenticated attacker with the 'Manage firmware updates' role to escalate their privileges on the underlying OS level.
CVE-2024-39871 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 6.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected applications do not properly separate the rights to edit device settings and to edit settings for communication relations. This could allow an authenticated attacker with the permission to manage devices to gain access to participant groups that the attacked does not belong to.
CVE-2024-39870 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 6.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected applications can be configured to allow users to manage own users. A local authenticated user with this privilege could use this modify users outside of their own scope as well as to escalate privileges.
CVE-2024-39869 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 6.5 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected products allow to upload certificates. An authenticated attacker could upload a crafted certificates leading to a permanent denial-of-service situation. In order to recover from such an attack, the offending certificate needs to be removed manually.
CVE-2024-39868 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 7.6 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit VxLAN configuration information of networks for which they have no privileges.
CVE-2024-39867 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 7.6 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). Affected devices do not properly validate the authentication when performing certain actions in the web interface allowing an unauthenticated attacker to access and edit device configuration information of devices for which they have no privileges.
CVE-2024-39866 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 N/A 8.8 HIGH
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP1). The affected application allows users to upload encrypted backup files. This could allow an attacker with access to the backup encryption key and with the right to upload backup files to create a user with administrative privileges.