Vulnerabilities (CVE)

Filtered by vendor Schneider-electric Subscribe
Total 767 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2023-28003 1 Schneider-electric 1 Ecostruxure Power Monitoring Expert 2024-11-21 N/A 6.7 MEDIUM
A CWE-613: Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain unauthorized access over a hijacked session in PME after the legitimate user has signed out of their account.
CVE-2023-27984 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27983 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27982 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 8.8 HIGH
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27981 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a victim tries to open a malicious report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27980 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 8.8 HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior)
CVE-2023-27979 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27978 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 7.8 HIGH
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27977 1 Schneider-electric 3 Custom Reports, Igss Dashboard, Igss Data Server 2024-11-21 N/A 6.5 MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior).
CVE-2023-27976 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 N/A 8.8 HIGH
A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)
CVE-2023-25620 1 Schneider-electric 16 140cpu65, 140cpu65 Firmware, Bmeh58s and 13 more 2024-11-21 N/A 6.5 MEDIUM
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user.
CVE-2023-25556 1 Schneider-electric 14 Merten Instabus Tastermodul 1fach System M, Merten Instabus Tastermodul 1fach System M Firmware, Merten Instabus Tastermodul 2fach System M and 11 more 2024-11-21 N/A 8.3 HIGH
A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the attacker has access to the KNX installation.
CVE-2023-25555 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 5.6 MEDIUM
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25554 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.8 HIGH
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalation on the appliance when a maliciously crafted Operating System command is entered on the device. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25553 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 6.1 MEDIUM
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25552 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.1 HIGH
A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthorized functions when tampering the Device File Transfer settings on DCE endpoints. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25551 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 6.1 MEDIUM
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25550 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.2 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when maliciously crafted hostname syntax is entered. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25549 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 7.2 HIGH
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DCE network settings endpoint. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)
CVE-2023-25548 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 N/A 8.8 HIGH
A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when a hacker is using a low privileged user. Affected products: StruxureWare Data Center Expert (V7.9.2 and prior)