Show plain JSON{"id": "CVE-2021-22824", "metrics": {"cvssMetricV2": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "acInsufInfo": false, "impactScore": 2.9, "baseSeverity": "MEDIUM", "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}], "cvssMetricV31": [{"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}]}, "published": "2022-02-11T18:15:09.617", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01", "tags": ["Patch", "Vendor Advisory"], "source": "cybersecurity@se.com"}, {"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01", "tags": ["Patch", "Vendor Advisory"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "cybersecurity@se.com", "description": [{"lang": "en", "value": "CWE-120"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-120"}]}], "descriptions": [{"lang": "en", "value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"}, {"lang": "es", "value": "Una CWE-120: Se presenta una vulnerabilidad de Copia del B\u00fafer sin Comprobar el Tama\u00f1o de la Entrada que podr\u00eda resultar en una denegaci\u00f3n de servicio, debido a una falta de comprobaci\u00f3n de la longitud de los datos suministrados por el usuario de un mensaje construido recibido en la red. Producto afectado: Interactive Graphical SCADA System Data Collector (dc.exe) (versiones V15.0.0.21320 y anteriores)"}], "lastModified": "2024-11-21T05:50:44.890", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_collector:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "BCC36B69-9234-4136-8A41-4AF378DD9842", "versionEndIncluding": "15.0.0.21320"}], "operator": "OR"}]}], "sourceIdentifier": "cybersecurity@se.com"}