Total
6045 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-44759 | 1 Nuserp | 1 Nus-m9 Erp | 2026-06-17 | N/A | 7.5 HIGH |
| An arbitrary file download vulnerability in the component /Doc/DownloadFile of NUS-M9 ERP Management Software v3.0.0 allows attackers to download arbitrary files and access sensitive information via a crafted interface request. | |||||
| CVE-2024-44678 | 2026-06-17 | N/A | 8.0 HIGH | ||
| Gigastone TR1 Travel Router R101 v1.0.2 is vulnerable to Command Injection. This allows an authenticated attacker to execute arbitrary commands on the device by sending a crafted HTTP request to the ssid parameter in the request. | |||||
| CVE-2024-44342 | 1 Dlink | 2 Dir-846w, Dir-846w Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the wl(0).(0)_ssid parameter. This vulnerability is exploited via a crafted POST request. | |||||
| CVE-2024-44341 | 1 Dlink | 2 Dir-846w, Dir-846w Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the lan(0)_dhcps_staticlist parameter. This vulnerability is exploited via a crafted POST request. | |||||
| CVE-2024-44340 | 1 Dlink | 2 Dir-846w, Dir-846w Firmware | 2026-06-17 | N/A | 8.8 HIGH |
| D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via keys smartqos_express_devices and smartqos_normal_devices in SetSmartQoSSettings. | |||||
| CVE-2024-44333 | 2026-06-17 | N/A | 8.8 HIGH | ||
| D-Link DI-7003GV2 v24.04.18D1, DI-7100G+V2 v24.04.18D1, DI-7100GV2 v24.04.18D1, DI-7200GV2 v24.04.18E1, DI-7300G+V2 v24.04.18D1, and DI-7400G+V2 v24.04.18D1 are vulnerable to Remote Command Execution. An attacker can achieve arbitrary command execution by sending a carefully crafted malicious string to the CGI function responsible for handling usb_paswd.asp. | |||||
| CVE-2024-44072 | 2026-06-17 | N/A | 5.7 MEDIUM | ||
| OS command injection vulnerability exists in BUFFALO wireless LAN routers and wireless LAN repeaters. If a user logs in to the management page and sends a specially crafted request to the affected product from the product's specific management page, an arbitrary OS command may be executed. | |||||
| CVE-2024-43804 | 1 Roxy-wi | 1 Roxy-wi | 2026-06-17 | N/A | 8.8 HIGH |
| Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. An OS Command Injection vulnerability allows any authenticated user on the application to execute arbitrary code on the web application server via port scanning functionality. User-supplied input is used without validation when constructing and executing an OS command. User supplied JSON POST data is parsed and if "id" JSON key does not exist, JSON value supplied via "ip" JSON key is assigned to the "ip" variable. Later on, "ip" variable which can be controlled by the attacker is used when constructing the cmd and cmd1 strings without any extra validation. Then, server_mod.subprocess_execute function is called on both cmd1 and cmd2. When the definition of the server_mod.subprocess_execute() function is analyzed, it can be seen that subprocess.Popen() is called on the input parameter with shell=True which results in OS Command Injection. This issue has not yet been patched. Users are advised to contact the Roxy-WI to coordinate a fix. | |||||
| CVE-2024-43778 | 2026-06-17 | N/A | 8.8 HIGH | ||
| OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings. | |||||
| CVE-2024-43657 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
| CVE-2024-43656 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
| CVE-2024-43655 | 2026-06-17 | N/A | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
| CVE-2024-43654 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
| CVE-2024-43653 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | |||||
| CVE-2024-43652 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. | |||||
| CVE-2024-43651 | 2026-06-17 | N/A | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | |||||
| CVE-2024-43650 | 2026-06-17 | N/A | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y). | |||||
| CVE-2024-43649 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y). | |||||
| CVE-2024-43648 | 2026-06-17 | N/A | 8.8 HIGH | ||
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). | |||||
| CVE-2024-43405 | 1 Projectdiscovery | 1 Nuclei | 2026-06-17 | N/A | 7.4 HIGH |
| Nuclei is a vulnerability scanner powered by YAML based templates. Starting in version 3.0.0 and prior to version 3.3.2, a vulnerability in Nuclei's template signature verification system could allow an attacker to bypass the signature check and possibly execute malicious code via custom code template. The vulnerability is present in the template signature verification process, specifically in the `signer` package. The vulnerability stems from a discrepancy between how the signature verification process and the YAML parser handle newline characters, combined with the way multiple signatures are processed. This allows an attacker to inject malicious content into a template while maintaining a valid signature for the benign part of the template. CLI users are affected if they execute custom code templates from unverified sources. This includes templates authored by third parties or obtained from unverified repositories. SDK Users are affected if they are developers integrating Nuclei into their platforms, particularly if they permit the execution of custom code templates by end-users. The vulnerability is addressed in Nuclei v3.3.2. Users are strongly recommended to update to this version to mitigate the security risk. As an interim measure, users should refrain from using custom templates if unable to upgrade immediately. Only trusted, verified templates should be executed. Those who are unable to upgrade Nuclei should disable running custom code templates as a workaround. | |||||
