Vulnerabilities (CVE)

Filtered by CWE-78
Total 6045 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-50388 1 Qnap 1 Hybrid Backup Sync 2026-06-17 N/A 9.8 CRITICAL
An OS command injection vulnerability has been reported to affect HBS 3 Hybrid Backup Sync. If exploited, the vulnerability could allow remote attackers to execute commands. We have already fixed the vulnerability in the following version: HBS 3 Hybrid Backup Sync 25.1.1.673 and later
CVE-2024-50377 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 6.5 MEDIUM
A CWE-798 "Use of Hard-coded Credentials" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability is associated to the backup configuration functionality that by default encrypts the archives using a static password.
CVE-2024-50376 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.3 HIGH
A CWE-79 "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited remotely leveraging a rogue Wi-Fi access point with a malicious SSID.
CVE-2024-50375 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-306 "Missing Authentication for Critical Function" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point.
CVE-2024-50374 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "capture_packages" operation.
CVE-2024-50373 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
CVE-2024-50372 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
CVE-2024-50371 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
CVE-2024-50370 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 9.8 CRITICAL
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "cfg_cmd_set_eth_conf" operation.
CVE-2024-50369 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50368 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "basic_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50367 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "sta_log_htm" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50366 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "applications_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50365 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "lan_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50364 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50363 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "mp_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50362 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "connection_profile_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50361 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "certificate_file_remove" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50360 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "snmp_apply" API which are not properly sanitized before being concatenated to OS level commands.
CVE-2024-50359 1 Advantech 6 Eki-6333ac-1gpo, Eki-6333ac-1gpo Firmware, Eki-6333ac-2g and 3 more 2026-06-17 N/A 7.2 HIGH
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.