CVE-2024-50369

A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "multiple_ssid_htm" API which are not properly sanitized before being concatenated to OS level commands.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*

History

23 Jan 2026, 18:14

Type Values Removed Values Added
First Time Advantech eki-6333ac-1gpo
Advantech eki-6333ac-2g Firmware
Advantech
Advantech eki-6333ac-1gpo Firmware
Advantech eki-6333ac-2g
Advantech eki-6333ac-2gd Firmware
Advantech eki-6333ac-2gd
References () https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50369 - () https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50369 - Third Party Advisory
CPE cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*
cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*
cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*
Summary
  • (es) Se descubrió una vulnerabilidad CWE-78 "Neutralización incorrecta de elementos especiales utilizados en un comando del SO ('Inyección de comandos del SO')" que afectaba a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (&lt;= 1.6.3), EKI-6333AC-2GD (&lt;= v1.6.3) y EKI-6333AC-1GPO (&lt;= v1.2.1). La fuente de la vulnerabilidad se basa en múltiples parámetros pertenecientes a la API "multiple_ssid_htm" que no se desinfectan correctamente antes de concatenarse con comandos de nivel del SO.

26 Nov 2024, 11:22

Type Values Removed Values Added
New CVE

Information

Published : 2024-11-26 11:22

Updated : 2026-01-23 18:14


NVD link : CVE-2024-50369

Mitre link : CVE-2024-50369

CVE.ORG link : CVE-2024-50369


JSON object : View

Products Affected

advantech

  • eki-6333ac-2g
  • eki-6333ac-2gd
  • eki-6333ac-2gd_firmware
  • eki-6333ac-1gpo
  • eki-6333ac-2g_firmware
  • eki-6333ac-1gpo_firmware
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')