Show plain JSON{"id": "CVE-2022-2788", "metrics": {"cvssMetricV31": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 3.9, "attackVector": "LOCAL", "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "LOW", "confidentialityImpact": "NONE"}, "impactScore": 2.5, "exploitabilityScore": 1.3}, {"type": "Primary", "source": "nvd@nist.gov", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.3, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.3}]}, "published": "2022-08-19T21:15:08.403", "references": [{"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "source": "ics-cert@hq.dhs.gov"}, {"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-06", "tags": ["Mitigation", "Third Party Advisory", "US Government Resource"], "source": "af854a3a-2127-422b-91ae-364da2661108"}], "vulnStatus": "Modified", "weaknesses": [{"type": "Secondary", "source": "ics-cert@hq.dhs.gov", "description": [{"lang": "en", "value": "CWE-29"}]}, {"type": "Primary", "source": "nvd@nist.gov", "description": [{"lang": "en", "value": "CWE-22"}]}], "descriptions": [{"lang": "en", "value": "Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '\\..\\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering station onto Windows in a way that executes the malicious code."}, {"lang": "es", "value": "Emerson Electrics Proficy Machine Edition versiones 9.80 y anteriores, es vulnerable a CWE-29 Salto de Ruta: '\\..\\Filename\", tambi\u00e9n se conoce como ataque ZipSlip, mediante un procedimiento de carga que permite a atacantes implantar un archivo .BLZ malicioso en el PLC. El archivo puede transferirse mediante la estaci\u00f3n de ingenier\u00eda a Windows de forma que sea ejecutado el c\u00f3digo malicioso."}], "lastModified": "2024-11-21T07:01:41.827", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:a:emerson:electric\\'s_proficy:*:*:*:*:machine:*:*:*", "vulnerable": true, "matchCriteriaId": "78333757-4370-4673-BE1C-B76FD6BE58C4", "versionEndIncluding": "9.80"}], "operator": "OR"}]}], "sourceIdentifier": "ics-cert@hq.dhs.gov"}