Filtered by vendor Mitsubishielectric
Subscribe
Total
161 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2022-24946 | 1 Mitsubishielectric | 64 L02cpu, L02cpu-p, L02cpu-p Firmware and 61 more | 2026-06-02 | 7.8 HIGH | 7.5 HIGH |
| Improper Resource Locking vulnerability in Mitsubishi Electric MELSEC iQ-R Series R12CCPU-V firmware versions "16" and prior, Mitsubishi Electric MELSEC-Q Series Q03UDECPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/10/13/20/26/50/100UDEHCPU the first 5 digits of serial No. "24061" and prior, Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q04/06/13/26UDPVCPU the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-Q Series Q12DCCPU-V all versions, Mitsubishi Electric MELSEC-Q Series Q24DHCCPU-V(G) all versions, Mitsubishi Electric MELSEC-Q Series Q24/26DHCCPU-LS all versions, Mitsubishi Electric MELSEC-L series L02/06/26CPU(-P) the first 5 digits of serial number "24051" and prior, Mitsubishi Electric MELSEC-L series L26CPU-(P)BT the first 5 digits of serial number "24051" and prior and Mitsubishi Electric MELIPC Series MI5122-VW firmware versions "05" and prior allows a remote unauthenticated attacker to cause a denial of service (DoS) condition in Ethernet communications by sending specially crafted packets. A system reset of the products is required for recovery. | |||||
| CVE-2016-8368 | 1 Mitsubishielectric | 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more | 2026-05-13 | 5.0 MEDIUM | 8.6 HIGH |
| An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock. | |||||
| CVE-2016-8370 | 1 Mitsubishielectric | 6 Qj71e71-100, Qj71e71-100 Firmware, Qj71e71-b2 and 3 more | 2026-05-13 | 5.0 MEDIUM | 7.5 HIGH |
| An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC. | |||||
| CVE-2026-1874 | 1 Mitsubishielectric | 4 Melsec Iq-f Fx5-eip, Melsec Iq-f Fx5-eip Firmware, Melsec Iq-f Fx5-enet\/ip and 1 more | 2026-05-04 | N/A | 7.5 HIGH |
| Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery. | |||||
| CVE-2026-1876 | 1 Mitsubishielectric | 2 Melsec Iq-f Fx5-enet\/ip, Melsec Iq-f Fx5-enet\/ip Firmware | 2026-04-30 | N/A | 7.5 HIGH |
| Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery. | |||||
| CVE-2026-1875 | 1 Mitsubishielectric | 2 Melsec Iq-f Fx5-eip, Melsec Iq-f Fx5-eip Firmware | 2026-04-30 | N/A | 7.5 HIGH |
| Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery. | |||||
| CVE-2013-2817 | 1 Mitsubishielectric | 1 Mc-worx Suite | 2026-04-29 | 9.3 HIGH | N/A |
| An ActiveX control in IcoLaunch.dll in Mitsubishi Electric Automation MC-WorX Suite 8.02 allows user-assisted remote attackers to execute arbitrary programs via a crafted HTML document in conjunction with a Login Client button click. | |||||
| CVE-2024-7587 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 7.8 HIGH |
| Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32. | |||||
| CVE-2022-33320 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes. | |||||
| CVE-2022-33319 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 8.2 HIGH |
| Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server. | |||||
| CVE-2022-33318 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 9.8 CRITICAL |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server. | |||||
| CVE-2022-33317 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 7.8 HIGH |
| Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. | |||||
| CVE-2022-33316 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | |||||
| CVE-2022-33315 | 2 Iconics, Mitsubishielectric | 2 Genesis64, Mc Works64 | 2026-01-09 | N/A | 7.8 HIGH |
| Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. | |||||
| CVE-2022-23130 | 2 Iconics, Mitsubishielectric | 3 Genesis64, Hyper Historian, Mc Works64 | 2026-01-08 | 4.3 MEDIUM | 5.9 MEDIUM |
| Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 and prior, Mitsubishi Electric GENESIS32 versions 9.7 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior allows an attacker to cause a DoS condition in the database server by getting a legitimate user to import a configuration file containing specially crafted stored procedures into GENESIS64, ICONICS Suite, MC Works64, or GENESIS32 and execute commands against the database from GENESIS64, ICONICS Suite, MC Works64, or GENESIS32. | |||||
| CVE-2022-29830 | 1 Mitsubishielectric | 1 Gx Works3 | 2025-11-07 | N/A | 9.1 CRITICAL |
| Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally. | |||||
| CVE-2022-29829 | 1 Mitsubishielectric | 1 Gx Works3 | 2025-11-07 | N/A | 6.8 MEDIUM |
| Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2 versions from 1.100E to 1.200J allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. | |||||
| CVE-2022-29825 | 1 Mitsubishielectric | 1 Gx Works3 | 2025-11-07 | N/A | 5.6 MEDIUM |
| Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. | |||||
| CVE-2023-6943 | 1 Mitsubishielectric | 10 Ezsocket, Fr Configurator2, Got1000 and 7 more | 2025-09-19 | N/A | 9.8 CRITICAL |
| Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products. | |||||
| CVE-2023-6942 | 1 Mitsubishielectric | 10 Ezsocket, Fr Configurator2, Got1000 and 7 more | 2025-09-19 | N/A | 7.5 HIGH |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally. | |||||