Filtered by vendor Siemens
Subscribe
Total
2187 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2017-2689 | 1 Siemens | 1 Ruggedcom Rox I | 2026-06-17 | 6.5 MEDIUM | 8.8 HIGH |
| Siemens RUGGEDCOM ROX I (all versions) allow an authenticated user to bypass access restrictions in the web interface at port 10000/TCP to obtain privileged file system access or change configuration settings. | |||||
| CVE-2017-2688 | 1 Siemens | 1 Ruggedcom Rox I | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF. | |||||
| CVE-2017-2687 | 1 Siemens | 1 Ruggedcom Rox I | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link. | |||||
| CVE-2017-2686 | 1 Siemens | 1 Ruggedcom Rox I | 2026-06-17 | 4.0 MEDIUM | 6.5 MEDIUM |
| Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information. | |||||
| CVE-2017-2685 | 1 Siemens | 3 Sinumerik Integrate Access Mymachine\/ethernet, Sinumerik Integrate Operate Client, Sinumerik Operate | 2026-06-17 | 5.8 MEDIUM | 7.4 HIGH |
| Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack. | |||||
| CVE-2017-2684 | 1 Siemens | 1 Simatic Logon | 2026-06-17 | 6.8 MEDIUM | 9.0 CRITICAL |
| Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication. | |||||
| CVE-2017-2683 | 1 Siemens | 1 Ruggedcom Network Management Software | 2026-06-17 | 4.3 MEDIUM | 8.2 HIGH |
| A non-privileged user of the Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could perform a persistent Cross-Site Scripting (XSS) attack, potentially resulting in obtaining administrative permissions. | |||||
| CVE-2017-2682 | 1 Siemens | 1 Ruggedcom Network Management Software | 2026-06-17 | 6.8 MEDIUM | 8.8 HIGH |
| The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request. | |||||
| CVE-2017-2681 | 1 Siemens | 155 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200 Pn Io and 152 more | 2026-06-17 | 6.1 MEDIUM | 6.5 MEDIUM |
| Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. | |||||
| CVE-2017-2680 | 1 Siemens | 183 S110 Pn, Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware and 180 more | 2026-06-17 | 6.1 MEDIUM | 6.5 MEDIUM |
| Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. | |||||
| CVE-2017-18922 | 5 Canonical, Fedoraproject, Libvncserver Project and 2 more | 16 Ubuntu Linux, Fedora, Libvncserver and 13 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| It was discovered that websockets.c in LibVNCServer prior to 0.9.12 did not properly decode certain WebSocket frames. A malicious attacker could exploit this by sending specially crafted WebSocket frames to a server, causing a heap-based buffer overflow. | |||||
| CVE-2017-14491 | 13 Arista, Arubanetworks, Canonical and 10 more | 29 Eos, Arubaos, Ubuntu Linux and 26 more | 2026-06-17 | 7.5 HIGH | 9.8 CRITICAL |
| Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response. | |||||
| CVE-2017-14023 | 1 Siemens | 2 Simatic Pcs7, Simatic Wincc | 2026-06-17 | 4.0 MEDIUM | 4.9 MEDIUM |
| An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. | |||||
| CVE-2017-13099 | 3 Arubanetworks, Siemens, Wolfssl | 4 Instant, Scalance W1750d, Scalance W1750d Firmware and 1 more | 2026-06-17 | 4.3 MEDIUM | 7.5 HIGH |
| wolfSSL prior to version 3.12.2 provides a weak Bleichenbacher oracle when any TLS cipher suite using RSA key exchange is negotiated. An attacker can recover the private key from a vulnerable wolfSSL application. This vulnerability is referred to as "ROBOT." | |||||
| CVE-2017-12741 | 1 Siemens | 76 Dk Standard Ethernet Controller, Dk Standard Ethernet Controller Firmware, Ek-ertec 200p and 73 more | 2026-06-17 | 7.8 HIGH | 7.5 HIGH |
| Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. | |||||
| CVE-2017-12740 | 1 Siemens | 1 Logo\! Soft Comfort | 2026-06-17 | 4.3 MEDIUM | 5.9 MEDIUM |
| Siemens LOGO! Soft Comfort (All versions before V8.2) lacks integrity verification of software packages downloaded via an unprotected communication channel. This could allow a remote attacker to manipulate the software package while performing a Man-in-the-Middle (MitM) attack. | |||||
| CVE-2017-12739 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2026-06-17 | 10.0 HIGH | 9.8 CRITICAL |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to execute arbitrary code on the affected device. | |||||
| CVE-2017-12738 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2026-06-17 | 4.3 MEDIUM | 6.1 MEDIUM |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into clicking on a malicious link. | |||||
| CVE-2017-12737 | 1 Siemens | 2 Sm-2556, Sm-2556 Firmware | 2026-06-17 | 5.0 MEDIUM | 5.3 MEDIUM |
| An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow unauthenticated remote attackers to obtain sensitive device information over the network. | |||||
| CVE-2017-12736 | 1 Siemens | 15 Ruggedcom, Ruggedcom Ros, Ruggedcom Rsl910 and 12 more | 2026-06-17 | 5.8 MEDIUM | 8.8 HIGH |
| After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions. | |||||