Filtered by vendor Siemens
Subscribe
Total
1901 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-37203 | 1 Siemens | 2 Nx 1980, Solid Edge | 2024-11-21 | 5.8 MEDIUM | 7.1 HIGH |
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations. | |||||
CVE-2021-37202 | 1 Siemens | 2 Nx 1980, Solid Edge | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. | |||||
CVE-2021-37201 | 1 Siemens | 1 Sinec Network Management System | 2024-11-21 | 6.8 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). The web interface of affected devices is vulnerable to a Cross-Site Request Forgery (CSRF) attack. This could allow an attacker to manipulate the SINEC NMS configuration by tricking an unsuspecting user with administrative privileges to click on a malicious link. | |||||
CVE-2021-37200 | 1 Siemens | 1 Sinec Network Management System | 2024-11-21 | 4.0 MEDIUM | 7.7 HIGH |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1). An attacker with access to the webserver of an affected system could download arbitrary files from the underlying filesystem by sending a specially crafted HTTP request. | |||||
CVE-2021-37199 | 1 Siemens | 4 Sinumerik 808d, Sinumerik 808d Firmware, Sinumerik 828d and 1 more | 2024-11-21 | 7.8 HIGH | 7.5 HIGH |
A vulnerability has been identified in SINUMERIK 808D (All versions), SINUMERIK 828D (All versions < V4.95). Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial-of-service in the device. | |||||
CVE-2021-37198 | 1 Siemens | 1 Comos | 2024-11-21 | 5.1 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS uses a flawed implementation of CSRF prevention. An attacker could exploit this vulnerability to perform cross-site request forgery attacks. | |||||
CVE-2021-37197 | 1 Siemens | 1 Comos | 2024-11-21 | 6.0 MEDIUM | 8.8 HIGH |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS is vulnerable to SQL injections. This could allow an attacker to execute arbitrary SQL statements. | |||||
CVE-2021-37196 | 1 Siemens | 1 Comos | 2024-11-21 | 3.5 LOW | 6.5 MEDIUM |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.3 (All versions >= V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS unpacks specially crafted archive files to relative paths. This vulnerability could allow an attacker to store files in any folder accessible by the COMOS Web webservice. | |||||
CVE-2021-37195 | 1 Siemens | 1 Comos | 2024-11-21 | 2.6 LOW | 6.1 MEDIUM |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS accepts arbitrary code as attachment to tasks. This could allow an attacker to inject malicious code that is executed when loading the attachment. | |||||
CVE-2021-37194 | 1 Siemens | 1 Comos | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS allows to upload and store arbitrary files at the webserver. This could allow an attacker to store malicious files. | |||||
CVE-2021-37186 | 1 Siemens | 12 Logo\! Cmr2020, Logo\! Cmr2020 Firmware, Logo\! Cmr2040 and 9 more | 2024-11-21 | 4.8 MEDIUM | 5.4 MEDIUM |
A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information. | |||||
CVE-2021-37185 | 1 Siemens | 95 Simatic Drive Controller Cpu 1504d Tf, Simatic Drive Controller Cpu 1504d Tf Firmware, Simatic Drive Controller Cpu 1507d Tf and 92 more | 2024-11-21 | 7.1 HIGH | 7.5 HIGH |
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. | |||||
CVE-2021-37184 | 1 Siemens | 1 Industrial Edge Management | 2024-11-21 | 6.8 MEDIUM | 9.8 CRITICAL |
A vulnerability has been identified in Industrial Edge Management (All versions < V1.3). An unauthenticated attacker could change the the password of any user in the system under certain circumstances. With this an attacker could impersonate any valid user on an affected system. | |||||
CVE-2021-37182 | 1 Siemens | 34 Scalance Xm408-4c, Scalance Xm408-4c Firmware, Scalance Xm408-4c L3 and 31 more | 2024-11-21 | 4.3 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device. | |||||
CVE-2021-37181 | 1 Siemens | 3 Cerberus Dms, Desigo Cc, Desigo Cc Compact | 2024-11-21 | 7.5 HIGH | 10.0 CRITICAL |
A vulnerability has been identified in Cerberus DMS V4.0 (All versions), Cerberus DMS V4.1 (All versions), Cerberus DMS V4.2 (All versions), Cerberus DMS V5.0 (All versions < v5.0 QU1), Desigo CC Compact V4.0 (All versions), Desigo CC Compact V4.1 (All versions), Desigo CC Compact V4.2 (All versions), Desigo CC Compact V5.0 (All versions < V5.0 QU1), Desigo CC V4.0 (All versions), Desigo CC V4.1 (All versions), Desigo CC V4.2 (All versions), Desigo CC V5.0 (All versions < V5.0 QU1). The application deserialises untrusted data without sufficient validations, that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system. The CCOM communication component used for Windows App / Click-Once and IE Web / XBAP client connectivity are affected by the vulnerability. | |||||
CVE-2021-37180 | 1 Siemens | 2 Solid Edge Se2021, Solid Edge Se2021 Firmware | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775) | |||||
CVE-2021-37179 | 1 Siemens | 2 Solid Edge Se2021, Solid Edge Se2021 Firmware | 2024-11-21 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777) | |||||
CVE-2021-37178 | 1 Siemens | 2 Solid Edge Se2021, Solid Edge Se2021 Firmware | 2024-11-21 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted xml file. | |||||
CVE-2021-37176 | 1 Siemens | 1 Simcenter Femap | 2024-11-21 | 4.3 MEDIUM | 3.3 LOW |
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260) | |||||
CVE-2021-37175 | 1 Siemens | 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices. |