| CVE-2024-3493 | 1 Rockwellautomation | 16 1756-en4tr, 1756-en4tr Firmware, Compact Guardlogix 5380 and 13 more | 2026-06-17 | N/A | 8.6 HIGH |
| A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF) Rockwell Automation's ControlLogix 5580, Guard Logix 5580, CompactLogix 5380, and 1756-EN4TR. If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, an MNRF could result in a loss of view and/or control of connected devices. | |||||
| CVE-2024-37369 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | N/A | 8.8 HIGH |
| A privilege escalation vulnerability exists in the affected product. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system. | |||||
| CVE-2024-37368 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | N/A | 7.5 HIGH |
| A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification. | |||||
| CVE-2024-37367 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | N/A | 7.5 HIGH |
| A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification. | |||||
| CVE-2024-37365 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | N/A | 7.3 HIGH |
| A remote code execution vulnerability exists in the affected product. The vulnerability allows users to save projects within the public directory allowing anyone with local access to modify and/or delete files. Additionally, a malicious user could potentially leverage this vulnerability to escalate their privileges by changing the macro to execute arbitrary code. | |||||
| CVE-2024-2929 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 7.8 HIGH |
| A memory corruption vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by corrupting the memory triggering an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-2427 | 1 Rockwellautomation | 2 Powerflex 527 Ac Drives, Powerflex 527 Ac Drives Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper traffic throttling in the device. If multiple data packets are sent to the device repeatedly the device will crash and require a manual restart to recover. | |||||
| CVE-2024-2426 | 1 Rockwellautomation | 2 Powerflex 527 Ac Drives, Powerflex 527 Ac Drives Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it. | |||||
| CVE-2024-2425 | 1 Rockwellautomation | 2 Powerflex 527 Ac Drives, Powerflex 527 Ac Drives Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it. | |||||
| CVE-2024-2424 | 1 Rockwellautomation | 2 5015-aenftxt, 5015-aenftxt Firmware | 2026-06-17 | N/A | 7.5 HIGH |
| An input validation vulnerability exists in the Rockwell Automation 5015-AENFTXT that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability. | |||||
| CVE-2024-21920 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 4.4 MEDIUM |
| A memory buffer vulnerability in Rockwell Automation Arena Simulation could potentially let a threat actor read beyond the intended memory boundaries. This could reveal sensitive information and even cause the application to crash, resulting in a denial-of-service condition. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-21919 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 7.8 HIGH |
| An uninitialized pointer in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by leveraging the pointer after it is properly. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-21918 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 7.8 HIGH |
| A memory buffer vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code to the software by corrupting the memory and triggering an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-21917 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2026-06-17 | N/A | 9.8 CRITICAL |
| A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of digital signing between the FTSP service token and directory. If exploited, a malicious user could potentially retrieve user information and modify settings without any authentication. | |||||
| CVE-2024-21916 | 1 Rockwellautomation | 6 Controllogix 5570 Controller, Controllogix 5570 Controller Firmware, Controllogix 5570 Redundant Controller and 3 more | 2026-06-17 | N/A | 8.6 HIGH |
| A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF. | |||||
| CVE-2024-21915 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2026-06-17 | N/A | 9.0 CRITICAL |
| A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and receive FTSP Administrator Group privileges. A threat actor could potentially read and modify sensitive data, delete data and render the FTSP system unavailable. | |||||
| CVE-2024-21914 | 1 Rockwellautomation | 1 Factorytalk View | 2026-06-17 | N/A | 5.3 MEDIUM |
| A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product. | |||||
| CVE-2024-21913 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 7.8 HIGH |
| A heap-based memory buffer overflow vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code into the software by overstepping the memory boundaries, which triggers an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-21912 | 1 Rockwellautomation | 1 Arena | 2026-06-17 | N/A | 7.8 HIGH |
| An arbitrary code execution vulnerability in Rockwell Automation Arena Simulation could let a malicious user insert unauthorized code into the software. This is done by writing beyond the designated memory area, which causes an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. | |||||
| CVE-2024-12672 | 2 Microsoft, Rockwellautomation | 2 Windows, Arena | 2026-06-17 | N/A | 7.3 HIGH |
| A third-party vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to write beyond the boundaries of allocated memory in a DOE file. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor. | |||||