Filtered by vendor Rockwellautomation
Subscribe
Total
338 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2014-5424 | 1 Rockwellautomation | 1 Connected Components Workbench | 2026-05-06 | 7.5 HIGH | N/A |
| Rockwell Automation Connected Components Workbench (CCW) before 7.00.00 allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via an invalid property value to an ActiveX control that was built with an outdated compiler. | |||||
| CVE-2015-6486 | 1 Rockwellautomation | 2 Micrologix 1100 Firmware, Micrologix 1400 Firmware | 2026-05-06 | 6.5 MEDIUM | N/A |
| SQL injection vulnerability on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors. | |||||
| CVE-2016-4531 | 1 Rockwellautomation | 1 Factorytalk Energrymetrix | 2026-05-06 | 7.5 HIGH | 7.3 HIGH |
| Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 does not invalidate credentials upon a logout action, which makes it easier for remote attackers to obtain access by leveraging an unattended workstation. | |||||
| CVE-2015-6491 | 1 Rockwellautomation | 2 Micrologix 1100 Firmware, Micrologix 1400 Firmware | 2026-05-06 | 4.0 MEDIUM | N/A |
| Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors. | |||||
| CVE-2016-2277 | 1 Rockwellautomation | 1 Integrated Architecture Builder | 2026-05-06 | 6.9 MEDIUM | 6.3 MEDIUM |
| IAB.exe in Rockwell Automation Integrated Architecture Builder (IAB) before 9.6.0.8 and 9.7.x before 9.7.0.2 allows remote attackers to execute arbitrary code via a crafted project file. | |||||
| CVE-2011-3489 | 1 Rockwellautomation | 1 Rslogix | 2026-04-29 | 5.0 MEDIUM | N/A |
| RnaUtility.dll in RsvcHost.exe 2.30.0.23 in Rockwell RSLogix 19 and earlier allows remote attackers to cause a denial of service (crash) via a crafted rna packet with a long string to TCP port 4446 that triggers (1) "a memset zero overflow" or (2) an out-of-bounds read, related to improper handling of a 32-bit size field. | |||||
| CVE-2012-4690 | 1 Rockwellautomation | 3 Ab Micrologix Controller, Plc-5 Controller, Slc 500 Controller | 2026-04-29 | 7.1 HIGH | N/A |
| Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits. | |||||
| CVE-2011-2530 | 1 Rockwellautomation | 2 Eds Hardware Installation Tool, Rslinx | 2026-04-29 | 9.3 HIGH | N/A |
| Buffer overflow in RSEds.dll in RSHWare.exe in the EDS Hardware Installation Tool 1.0.5.1 and earlier in Rockwell Automation RSLinx Classic before 2.58 allows user-assisted remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a malformed .eds file. | |||||
| CVE-2012-6439 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2026-04-29 | 8.5 HIGH | N/A |
| When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that changes the product’s configuration and network parameters, a DoS condition can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
| CVE-2012-0221 | 1 Rockwellautomation | 2 Factorytalk, Rslogix 5000 | 2026-04-29 | 5.0 MEDIUM | N/A |
| The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 does not properly handle the return value from an unspecified function, which allows remote attackers to cause a denial of service (service outage) via a crafted packet. | |||||
| CVE-2014-0755 | 1 Rockwellautomation | 2 Logix 5000 Controller, Rslogix 5000 Design And Configuration Software | 2026-04-29 | 6.3 MEDIUM | N/A |
| Rockwell Automation RSLogix 5000 7 through 20.01, and 21.0, does not properly implement password protection for .ACD files (aka project files), which allows local users to obtain sensitive information or modify data via unspecified vectors. | |||||
| CVE-2012-6441 | 1 Rockwellautomation | 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more | 2026-04-29 | 5.0 MEDIUM | N/A |
| An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP. Successful exploitation of this vulnerability could cause loss of confidentiality. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 | |||||
| CVE-2012-4713 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2026-04-29 | 7.8 HIGH | N/A |
| Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a negative integer value. | |||||
| CVE-2012-4715 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2026-04-29 | 10.0 HIGH | N/A |
| Buffer overflow in LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via a UDP packet with a certain integer length value that is (1) too large or (2) too small, leading to improper handling by Logger.dll. | |||||
| CVE-2012-0222 | 1 Rockwellautomation | 2 Factorytalk, Rslogix 5000 | 2026-04-29 | 5.0 MEDIUM | N/A |
| The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet. | |||||
| CVE-2012-4695 | 1 Rockwellautomation | 1 Rslinx Enterprise | 2026-04-29 | 7.1 HIGH | N/A |
| LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage) via a zero-byte UDP packet that is not properly handled by Logger.dll. | |||||
| CVE-2012-4714 | 1 Rockwellautomation | 1 Factorytalk Services Platform | 2026-04-29 | 7.8 HIGH | N/A |
| Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service (service outage or RNADiagReceiver.exe daemon crash) via UDP data that specifies a large integer value. | |||||
| CVE-2011-2957 | 1 Rockwellautomation | 1 Factorytalk Diagnostics Viewer | 2026-04-29 | 6.9 MEDIUM | N/A |
| Unspecified vulnerability in Rockwell Automation FactoryTalk Diagnostics Viewer before V2.30.00 (CPR9 SR3) allows local users to execute arbitrary code via a crafted FactoryTalk Diagnostics Viewer (.ftd) configuration file, which triggers memory corruption. | |||||
| CVE-2009-3739 | 1 Rockwellautomation | 2 Ab Micrologix Controller 1100, Ab Micrologix Controller 1400 | 2026-04-23 | 10.0 HIGH | N/A |
| Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors. | |||||
| CVE-2009-0472 | 1 Rockwellautomation | 1 Controllogix 1756-enbt\/a Ethernet\/ Ip Bridge | 2026-04-23 | 4.3 MEDIUM | N/A |
| Multiple cross-site scripting (XSS) vulnerabilities in the web interface in the Rockwell Automation ControlLogix 1756-ENBT/A EtherNet/IP Bridge Module allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||||