Filtered by vendor Siemens
Subscribe
Total
2002 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2016-2200 | 1 Siemens | 15 Simatic S7-1500 Cpu Firmware, Simatic S7-1511-1 Pn Cpu, Simatic S7-1511c-1 Pn Cpu and 12 more | 2025-04-12 | 7.8 HIGH | 7.5 HIGH |
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102. | |||||
CVE-2015-1596 | 1 Siemens | 1 Spcanywhere | 2025-04-12 | 5.8 MEDIUM | N/A |
The Siemens SPCanywhere application for Android and iOS does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | |||||
CVE-2014-2909 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 5.8 MEDIUM | N/A |
CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors. | |||||
CVE-2014-2254 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets, a different vulnerability than CVE-2014-2255. | |||||
CVE-2015-5717 | 1 Siemens | 1 Compas | 2025-04-12 | 5.8 MEDIUM | N/A |
The Siemens COMPAS Mobile application before 1.6 for Android does not properly verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate. | |||||
CVE-2014-2257 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets. | |||||
CVE-2015-1449 | 1 Siemens | 5 Ruggedcom Firmware, Ruggedcom Win5100, Ruggedcom Win5200 and 2 more | 2025-04-12 | 10.0 HIGH | N/A |
Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote attackers to execute arbitrary code via unspecified vectors. | |||||
CVE-2016-9155 | 1 Siemens | 30 Ccid1445-dn18, Ccid1445-dn18 Firmware, Ccid1445-dn28 and 27 more | 2025-04-12 | 5.0 MEDIUM | 9.8 CRITICAL |
The following SIEMENS branded IP Camera Models CCMW3025, CVMW3025-IR, CFMW3025 prior to version 1.41_SP18_S1; CCPW3025, CCPW5025 prior to version 0.1.73_S1; CCMD3025-DN18 prior to version v1.394_S1; CCID1445-DN18, CCID1445-DN28, CCID1145-DN36, CFIS1425, CCIS1425, CFMS2025, CCMS2025, CVMS2025-IR, CFMW1025, CCMW1025 prior to version v2635_SP1 could allow an attacker with network access to the web server to obtain administrative credentials under certain circumstances. | |||||
CVE-2015-5084 | 1 Siemens | 2 Simatic Wincc Sm\@rtclient, Simatic Wincc Sm\@rtclient Lite | 2025-04-12 | 2.1 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors. | |||||
CVE-2016-3963 | 1 Siemens | 1 Scalance S613 | 2025-04-12 | 5.0 MEDIUM | 5.3 MEDIUM |
Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443. | |||||
CVE-2014-9369 | 1 Siemens | 6 Spc4000, Spc4000 Firmware, Spc5000 and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SPC controllers SPC4000, SPC5000, and SPC6000 before 3.6.0 allow remote attackers to cause a denial of service (device restart) via crafted packets. | |||||
CVE-2016-9159 | 1 Siemens | 21 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 314, Simatic S7-300 Cpu 315-2 Dp and 18 more | 2025-04-12 | 4.3 MEDIUM | 5.9 MEDIUM |
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices. | |||||
CVE-2014-5231 | 2 Apple, Siemens | 2 Iphone Os, Simatic Wincc Sm\@rtclient | 2025-04-12 | 2.1 LOW | N/A |
The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. | |||||
CVE-2016-4955 | 6 Novell, Ntp, Opensuse and 3 more | 11 Suse Manager, Ntp, Leap and 8 more | 2025-04-12 | 4.3 MEDIUM | 5.9 MEDIUM |
ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service (peer-variable clearing and association outage) by sending (1) a spoofed crypto-NAK packet or (2) a packet with an incorrect MAC value at a certain time. | |||||
CVE-2015-3610 | 1 Siemens | 1 Homecontrol For Room Automation | 2025-04-12 | 5.4 MEDIUM | N/A |
The Siemens HomeControl for Room Automation application before 2.0.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information or modify data via a crafted certificate. | |||||
CVE-2015-5698 | 1 Siemens | 2 Simatic S7 1200 Cpu, Simatic S7 1200 Cpu Firmware | 2025-04-12 | 7.5 HIGH | N/A |
Cross-site request forgery (CSRF) vulnerability in the web server on Siemens SIMATIC S7-1200 CPU devices with firmware before 4.1.3 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | |||||
CVE-2014-2252 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 6.1 MEDIUM | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted PROFINET packets, a different vulnerability than CVE-2014-2253. | |||||
CVE-2014-2258 | 1 Siemens | 6 Simatic S7 Cpu-1211c, Simatic S7 Cpu 1200 Firmware, Simatic S7 Cpu 1212c and 3 more | 2025-04-12 | 7.8 HIGH | N/A |
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets, a different vulnerability than CVE-2014-2259. | |||||
CVE-2014-2253 | 1 Siemens | 1 Simatic S7-1500 Cpu Firmware | 2025-04-12 | 6.1 MEDIUM | N/A |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets. | |||||
CVE-2015-2822 | 1 Siemens | 1 Wincc | 2025-04-12 | 4.3 MEDIUM | N/A |
Siemens SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2 and SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2 allow man-in-the-middle attackers to cause a denial of service via crafted packets on TCP port 102. |