CVE-2024-45463 1 Siemens 1 Tecnomatix Plant Simulation 2026-06-17 N/A 7.8 HIGH
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-45385 1 Siemens 1 Industrial Edge Management 2026-06-17 N/A 4.7 MEDIUM
A vulnerability has been identified in Industrial Edge Management OS (IEM-OS) (All versions). Affected components are vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.
CVE-2024-44102 1 Siemens 1 Telecontrol Server Basic 2026-06-17 N/A 10.0 CRITICAL
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
CVE-2024-42345 1 Siemens 1 Sinema Remote Connect Server 2026-06-17 N/A 4.3 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session establishment and invalidation. This could allow a remote attacker to circumvent the additional multi factor authentication for user session establishment.
CVE-2024-42344 1 Siemens 1 Sinema Remote Connect Client 2026-06-17 N/A 4.4 MEDIUM
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application inserts sensitive information into a log file which is readable by all legitimate users of the underlying system. This could allow an authenticated attacker to compromise the confidentiality of other users' configuration data.
CVE-2024-41986 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 6.4 MEDIUM
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
CVE-2024-41985 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 2.6 LOW
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle.
CVE-2024-41984 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 2.6 LOW
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications.
CVE-2024-41983 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 3.5 LOW
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool.
CVE-2024-41982 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 4.8 MEDIUM
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information.
CVE-2024-41980 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 3.1 LOW
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information.
CVE-2024-41979 1 Siemens 1 Opcenter Quality 2026-06-17 N/A 7.1 HIGH
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.
CVE-2024-41978 1 Siemens 52 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 49 more 2026-06-17 N/A 6.5 MEDIUM
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices insert sensitive information about the generation of 2FA tokens into log files. This could allow an authenticated remote attacker to forge 2FA tokens of other users.
CVE-2024-41977 1 Siemens 52 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 49 more 2026-06-17 N/A 7.1 HIGH
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly enforce isolation between user sessions in their web server component. This could allow an authenticated remote attacker to escalate their privileges on the devices.
CVE-2024-41976 1 Siemens 52 Ruggedcom Rm1224 Lte\(4g\) Eu, Ruggedcom Rm1224 Lte\(4g\) Eu Firmware, Ruggedcom Rm1224 Lte\(4g\) Nam and 49 more 2026-06-17 N/A 7.2 HIGH
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.1), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.1), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.1), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.1), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.1), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.1), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.1), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.1), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.1), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.1). Affected devices do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device.
CVE-2024-41941 1 Siemens 1 Sinec Nms 2026-06-17 N/A 4.3 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and modify settings in the application without authorization.
CVE-2024-41940 1 Siemens 1 Sinec Nms 2026-06-17 N/A 9.1 CRITICAL
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly validate user input to a privileged command queue. This could allow an authenticated attacker to execute OS commands with elevated privileges.
CVE-2024-41939 1 Siemens 1 Sinec Nms 2026-06-17 N/A 8.8 HIGH
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could allow an authenticated attacker to bypass the checks and elevate their privileges on the application.
CVE-2024-41938 1 Siemens 1 Sinec Nms 2026-06-17 N/A 5.5 MEDIUM
A vulnerability has been identified in SINEC NMS (All versions < V3.0). The importCertificate function of the SINEC NMS Control web application contains a path traversal vulnerability. This could allow an authenticated attacker it to delete arbitrary certificate files on the drive SINEC NMS is installed on.
CVE-2024-41907 1 Siemens 1 Sinec Traffic Analyzer 2026-06-17 N/A 4.2 MEDIUM
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack.