Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1913 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2012-3040 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-04-11 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
CVE-2011-4056 1 Siemens 1 Tecnomatix Factorylink 2025-04-11 5.8 MEDIUM N/A
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
CVE-2013-0670 1 Siemens 1 Wincc Tia Portal 2025-04-11 4.3 MEDIUM N/A
CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.
CVE-2013-0674 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 6.8 MEDIUM N/A
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.
CVE-2011-4531 1 Siemens 1 Automation License Manager 2025-04-11 5.0 MEDIUM N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2013-6920 1 Siemens 14 Sinamics G110, Sinamics G110d, Sinamics G120 and 11 more 2025-04-11 10.0 HIGH N/A
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
CVE-2013-3633 1 Siemens 7 Scalance X200-4p Irt, Scalance X200irt Firmware, Scalance X201-3p Irt and 4 more 2025-04-11 8.0 HIGH N/A
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account.
CVE-2013-0700 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-04-11 7.8 HIGH N/A
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
CVE-2012-2598 1 Siemens 1 Wincc 2025-04-11 4.3 MEDIUM N/A
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
CVE-2012-3003 1 Siemens 1 Wincc 2025-04-11 5.8 MEDIUM N/A
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.
CVE-2012-4698 1 Siemens 4 Ros, Rox I Os, Rox Ii Os and 1 more 2025-04-11 4.3 MEDIUM N/A
Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers and decrypt network traffic by leveraging the availability of these keys within ROS files at all customer installations.
CVE-2012-2597 1 Siemens 1 Wincc 2025-04-11 4.0 MEDIUM N/A
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.
CVE-2014-1697 1 Siemens 1 Simatic Wincc Open Architecture 2025-04-11 7.5 HIGH N/A
The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.
CVE-2012-4691 1 Siemens 1 Automation License Manager 2025-04-11 3.3 LOW N/A
Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.
CVE-2013-0667 1 Siemens 1 Wincc Tia Portal 2025-04-11 4.3 MEDIUM N/A
Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.
CVE-2013-4781 1 Siemens 2 Enterprise Openscape Branch, Openscape Session Border Controller 2025-04-11 10.0 HIGH N/A
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspecified vectors.
CVE-2013-2780 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-04-11 7.8 HIGH N/A
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
CVE-2013-0676 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 4.0 MEDIUM N/A
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
CVE-2012-3034 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 4.3 MEDIUM N/A
WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.
CVE-2013-0671 1 Siemens 1 Wincc Tia Portal 2025-04-11 4.0 MEDIUM N/A
Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.