Vulnerabilities (CVE)

Filtered by vendor Siemens Subscribe
Total 1901 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2013-6925 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-11 8.3 HIGH N/A
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote attackers to hijack web sessions by predicting a session id value.
CVE-2012-1802 1 Siemens 10 Scalance X-300, Scalance X-300 Firmware, Scalance X-300eec and 7 more 2025-04-11 7.8 HIGH N/A
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
CVE-2012-1803 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-11 8.5 HIGH N/A
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
CVE-2013-3957 1 Siemens 2 Simatic Pcs7, Wincc 2025-04-11 7.5 HIGH N/A
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
CVE-2014-1966 1 Siemens 3 Ruggedcom Rs950g, Ruggedcom Rsg2488, Ruggedcom Rugged Operating System 2025-04-11 7.8 HIGH N/A
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
CVE-2014-1699 1 Siemens 1 Simatic Wincc Open Architecture 2025-04-11 5.0 MEDIUM N/A
Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.
CVE-2013-6926 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-11 8.0 HIGH N/A
The integrated HTTPS server in Siemens RuggedCom ROS before 3.12.2 allows remote authenticated users to bypass intended restrictions on administrative actions by leveraging access to a (1) guest or (2) operator account.
CVE-2011-4875 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 9.3 HIGH N/A
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
CVE-2022-31766 1 Siemens 32 Ruggedcom Rm1224, Ruggedcom Rm1224 Firmware, Scalance M804pb and 29 more 2025-04-10 N/A 8.6 HIGH
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.1.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.1.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.1.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.1.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.1.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.1.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.1.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.1.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.1.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.1.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.1.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.1.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.1.2), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions >= V1.1.0 < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions >= V1.1.0 < V3.0.0). Affected devices with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources.
CVE-2023-28831 1 Siemens 156 Simatic Cloud Connect 7 Cc712, Simatic Cloud Connect 7 Cc712 Firmware, Simatic Cloud Connect 7 Cc716 and 153 more 2025-04-10 N/A 7.5 HIGH
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.
CVE-2022-22965 5 Cisco, Oracle, Siemens and 2 more 39 Cx Cloud Agent, Commerce Platform, Communications Cloud Native Core Automated Test Suite and 36 more 2025-04-10 7.5 HIGH 9.8 CRITICAL
A Spring MVC or Spring WebFlux application running on JDK 9+ may be vulnerable to remote code execution (RCE) via data binding. The specific exploit requires the application to run on Tomcat as a WAR deployment. If the application is deployed as a Spring Boot executable jar, i.e. the default, it is not vulnerable to the exploit. However, the nature of the vulnerability is more general, and there may be other ways to exploit it.
CVE-2008-3972 2 Opensc-project, Siemens 2 Opensc, Cardos 2025-04-09 6.6 MEDIUM N/A
pkcs15-tool in OpenSC before 0.11.6 does not apply security updates to a smart card unless the card's label matches the "OpenSC" string, which might allow physically proximate attackers to exploit vulnerabilities that the card owner expected were patched, as demonstrated by exploitation of CVE-2008-2235.
CVE-2009-3322 1 Siemens 1 Gigaset Se361 Wlan Router 2025-04-09 7.8 HIGH N/A
The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.
CVE-2008-1267 1 Siemens 1 Speedstream 6520 2025-04-09 7.8 HIGH N/A
The Siemens SpeedStream 6520 router allows remote attackers to cause a denial of service (web interface crash) via an HTTP request to basehelp_English.htm with a large integer in the Content-Length field.
CVE-2008-2235 2 Opensc-project, Siemens 2 Opensc, Cardos 2025-04-09 4.9 MEDIUM N/A
OpenSC before 0.11.5 uses weak permissions (ADMIN file control information of 00) for the 5015 directory on smart cards and USB crypto tokens running Siemens CardOS M4, which allows physically proximate attackers to change the PIN.
CVE-2008-7065 1 Siemens 2 Gigaset C450 Ip, Gigaset C475 Ip 2025-04-09 7.8 HIGH N/A
Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060.
CVE-2007-1918 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2025-04-09 5.0 MEDIUM N/A
The RFC_SET_REG_SERVER_PROPERTY function in the SAP RFC Library 6.40 and 7.00 before 20070109 implements an option for exclusive access to an RFC server, which allows remote attackers to cause a denial of service (client lockout) via unspecified vectors. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2008-6993 1 Siemens 1 Gigaset Wlan Camera 2025-04-09 10.0 HIGH N/A
Siemens Gigaset WLAN Camera 1.27 has an insecure default password, which allows remote attackers to conduct unauthorized activities. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
CVE-2007-1913 8 Apple, Hp, Ibm and 5 more 11 Macos, Hp-ux, Tru64 and 8 more 2025-04-09 5.0 MEDIUM N/A
The TRUSTED_SYSTEM_SECURITY function in the SAP RFC Library 6.40 and 7.00 before 20061211 allows remote attackers to verify the existence of users and groups on systems and domains via unspecified vectors, a different vulnerability than CVE-2006-6010. NOTE: This information is based upon a vague initial disclosure. Details will be updated after the grace period has ended.
CVE-2008-6916 2 John Doe, Siemens 2 Netport Software, Speedstream 5200 2025-04-09 10.0 HIGH N/A
Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname.