Total
33 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-47490 | 1 Juniper | 7 Acx7020, Acx7024, Acx7024x and 4 more | 2026-01-26 | N/A | 8.2 HIGH |
| An Improper Restriction of Communication Channel to Intended Endpoints vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS Evolved on ACX 7000 Series allows an unauthenticated, network based attacker to cause increased consumption of resources, ultimately resulting in a Denial of Service (DoS). When specific transit MPLS packets are received by the PFE, these packets are internally forwarded to the Routing Engine (RE), rather than being handled appropriately. Continuous receipt of these MPLS packets causes resources to be exhausted. MPLS config is not required to be affected by this issue. This issue affects Junos OS Evolved ACX 7000 Series: * All versions before 21.4R3-S9-EVO, * 22.2-EVO before 22.2R3-S4-EVO, * 22.3-EVO before 22.3R3-S3-EVO, * 22.4-EVO before 22.4R3-S2-EVO, * 23.2-EVO before 23.2R2-EVO, * 23.4-EVO before 23.4R1-S1-EVO, 23.4R2-EVO. | |||||
| CVE-2025-58742 | 2026-01-26 | N/A | N/A | ||
| Insufficiently Protected Credentials, Improper Restriction of Communication Channel to Intended Endpoints vulnerability in the Connection Settings dialog in Milner ImageDirector Capture on Windows allows Adversary in the Middle (AiTM) by modifying the 'Server' field to redirect client authentication.This issue affects ImageDirector Capture: from 7.0.9 before 7.6.3.25808. | |||||
| CVE-2024-39537 | 1 Juniper | 7 Acx7020, Acx7024, Acx7024x and 4 more | 2026-01-22 | N/A | 6.5 MEDIUM |
| An Improper Restriction of Communication Channel to Intended Endpoints vulnerability in Juniper Networks Junos OS Evolved on ACX 7000 Series allows an unauthenticated, network-based attacker to cause a limited information disclosure and availability impact to the device. Due to a wrong initialization, specific processes which should only be able to communicate internally within the device can be reached over the network via open ports. This issue affects Junos OS Evolved on ACX 7000 Series: * All versions before 21.4R3-S7-EVO, * 22.2-EVO versions before 22.2R3-S4-EVO, * 22.3-EVO versions before 22.3R3-S3-EVO, * 22.4-EVO versions before 22.4R3-S2-EVO, * 23.2-EVO versions before 23.2R2-EVO, * 23.4-EVO versions before 23.4R1-S1-EVO, 23.4R2-EVO. | |||||
| CVE-2025-61939 | 1 Columbiaweather | 2 Weather Microserver, Weather Microserver Firmware | 2026-01-22 | N/A | 8.8 HIGH |
| An unused function in MicroServer can start a reverse SSH connection to a vendor registered domain, without mutual authentication. An attacker on the local network with admin access to the web server, and the ability to manipulate DNS responses, can redirect the SSH connection to an attacker controlled device. | |||||
| CVE-2025-33176 | 2025-11-06 | N/A | 6.2 MEDIUM | ||
| NVIDIA RunAI for all platforms contains a vulnerability where a user could cause an improper restriction of communications channels on an adjacent network. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, and information disclosure. | |||||
| CVE-2025-12357 | 2025-11-04 | N/A | 8.3 HIGH | ||
| By manipulating the Signal Level Attenuation Characterization (SLAC) protocol with spoofed measurements, an attacker can stage a man-in-the-middle attack between an electric vehicle and chargers that comply with the ISO 15118-2 part. This vulnerability may be exploitable wirelessly, within close proximity, via electromagnetic induction. | |||||
| CVE-2025-49734 | 1 Microsoft | 13 Powershell, Windows 10 1607, Windows 10 1809 and 10 more | 2025-10-02 | N/A | 7.0 HIGH |
| Improper restriction of communication channel to intended endpoints in Windows PowerShell allows an authorized attacker to elevate privileges locally. | |||||
| CVE-2017-3891 | 1 Blackberry | 1 Qnx Software Development Platform | 2025-08-22 | 6.8 MEDIUM | 9.6 CRITICAL |
| In BlackBerry QNX Software Development Platform (SDP) 6.6.0, an elevation of privilege vulnerability in the default configuration of the QNX SDP with QNet enabled on networks comprising two or more QNet nodes could allow an attacker to access local and remote files or take ownership of files on other QNX nodes regardless of permissions by executing commands targeting arbitrary nodes from a secondary QNX 6.6.0 QNet node. | |||||
| CVE-2025-48807 | 1 Microsoft | 12 Windows 10 1607, Windows 10 1809, Windows 10 21h2 and 9 more | 2025-08-21 | N/A | 6.7 MEDIUM |
| Improper restriction of communication channel to intended endpoints in Windows Hyper-V allows an authorized attacker to execute code locally. | |||||
| CVE-2024-22315 | 1 Ibm | 3 Storage Fusion, Storage Fusion Hci, Storage Fusion Hci For Watsonx | 2025-08-19 | N/A | 4.0 MEDIUM |
| IBM Fusion and IBM Fusion HCI 2.3.0 through 2.8.2 is vulnerable to insecure network connection by allowing an attacker who gains access to a Fusion container to establish an external network connection. | |||||
| CVE-2022-43916 | 2 Ibm, Redhat | 2 App Connect Enterprise Certified Container, Openshift | 2025-08-13 | N/A | 6.8 MEDIUM |
| IBM App Connect Enterprise Certified Container 7.1, 7.2, 8.0, 8.1, 8.2, 9.0, 9.1, 9.2, 10.0, 10.1, 11.0, 11.1, 11.2, 11.3, 11.4, 11.5, 11.6, 12.0, 12.1, 12.2, 12.3, 12.4, 12.5, 12.6, and 12.7 Pods do not restrict network egress for Pods that are used for internal infrastructure. | |||||
| CVE-2025-22251 | 1 Fortinet | 1 Fortios | 2025-07-25 | N/A | 3.1 LOW |
| An improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in FortiOS 7.6.0, 7.4.0 through 7.4.5, 7.2 all versions, 7.0 all versions, 6.4 all versions may allow an unauthenticated attacker to inject unauthorized sessions via crafted FGSP session synchronization packets. | |||||
| CVE-2024-26013 | 1 Fortinet | 6 Fortianalyzer, Fortimanager, Fortios and 3 more | 2025-07-25 | N/A | 7.5 HIGH |
| A improper restriction of communication channel to intended endpoints vulnerability [CWE-923] in Fortinet FortiOS version 7.4.0 through 7.4.4, 7.2.0 through 7.2.8, 7.0.0 through 7.0.15, 6.4.0 through 6.4.15 and before 6.2.16, Fortinet FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9 and before 7.0.15, Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and before 6.2.13, Fortinet FortiAnalyzer version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14 and before 6.2.13, Fortinet FortiVoice version 7.0.0 through 7.0.2 before 6.4.8 and Fortinet FortiWeb before 7.4.2 may allow an unauthenticated attacker in a man-in-the-middle position to impersonate the management device (FortiCloud server or/and in certain conditions, FortiManager), via intercepting the FGFM authentication request between the management device and the managed device | |||||
| CVE-2025-29986 | 1 Dell | 1 Common Event Enabler | 2025-07-15 | N/A | 8.3 HIGH |
| Dell Common Event Enabler, version(s) CEE 9.0.0.0, contain(s) an Improper Restriction of Communication Channel to Intended Endpoints vulnerability in the Common Anti-Virus Agent (CAVA). An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to Unauthorized access. | |||||
| CVE-2021-38487 | 1 Rti | 3 Connext Dds Micro, Connext Professional, Connext Secure | 2025-06-23 | 6.4 MEDIUM | 8.2 HIGH |
| RTI Connext Professional versions 4.1 to 6.1.0, and Connext Micro versions 2.4 and later are vulnerable when an attacker sends a specially crafted packet to flood target devices with unwanted traffic. This may result in a denial-of-service condition and information exposure. | |||||
| CVE-2025-32886 | 1 Gotenna | 3 Gotenna, Mesh, Mesh Firmware | 2025-06-20 | N/A | 4.0 MEDIUM |
| An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. All packets sent over RF are also sent over UART with USB Shell, allowing someone with local access to gain information about the protocol and intercept sensitive data. | |||||
| CVE-2025-35978 | 2025-06-12 | N/A | 7.1 HIGH | ||
| Improper restriction of communication channel to intended endpoints issue exists in UpdateNavi V1.4 L10 to L33 and UpdateNaviInstallService Service 1.2.0091 to 1.2.0125. If a local authenticated attacker send malicious data, an arbitrary registry value may be modified or arbitrary code may be executed. | |||||
| CVE-2025-20261 | 2025-06-05 | N/A | 8.8 HIGH | ||
| A vulnerability in the SSH connection handling of Cisco Integrated Management Controller (IMC) for Cisco UCS B-Series, UCS C-Series, UCS S-Series, and UCS X-Series Servers could allow an authenticated, remote attacker to access internal services with elevated privileges. This vulnerability is due to insufficient restrictions on access to internal services. An attacker with a valid user account could exploit this vulnerability by using crafted syntax when connecting to the Cisco IMC of an affected device through SSH. A successful exploit could allow the attacker to access internal services with elevated privileges, which may allow unauthorized modifications to the system, including the possibility of creating new administrator accounts on the affected device. | |||||
| CVE-2025-48999 | 1 Dataease | 1 Dataease | 2025-06-05 | N/A | 8.8 HIGH |
| DataEase is an open source business intelligence and data visualization tool. A bypass of CVE-2025-46566's patch exists in versions prior to 2.10.10. In a malicious payload, `getUrlType()` retrieves `hostName`. Since the judgment statement returns false, it will not enter the if statement and will not be filtered. The payload can be directly concatenated at the replace location to construct a malicious JDBC statement. Version 2.10.10 contains a patch for the issue. | |||||
| CVE-2025-46566 | 1 Dataease | 1 Dataease | 2025-05-28 | N/A | 9.8 CRITICAL |
| DataEase is an open-source BI tool alternative to Tableau. Prior to version 2.10.9, authenticated users can complete RCE through the backend JDBC link. This issue has been patched in version 2.10.9. | |||||
