Vulnerabilities (CVE)

Filtered by CWE-787
Total 12285 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-2893 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2894 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2895 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2896 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2899 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2898 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2900 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2901 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2902 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2891 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-2581 1 Tenda 2 Ac10, Ac10 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.
CVE-2024-2903 1 Tenda 2 Ac7, Ac7 Firmware 2025-01-22 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-27217 1 Belkin 2 F7c063, F7c063 Firmware 2025-01-22 N/A 9.8 CRITICAL
A stack-based buffer overflow in the ChangeFriendlyName() function of Belkin Smart Outlet V2 F7c063 firmware_2.00.11420.OWRT.PVT_SNSV2 allows attackers to cause a Denial of Service (DoS) via a crafted UPNP request.
CVE-2023-6749 1 Zephyrproject 1 Zephyr 2025-01-22 N/A 8.0 HIGH
Unchecked length coming from user input in settings shell
CVE-2024-23606 2 Fedoraproject, Libbiosig Project 2 Fedora, Libbiosig 2025-01-22 N/A 9.8 CRITICAL
An out-of-bounds write vulnerability exists in the sopen_FAMOS_read functionality of The Biosig Project libbiosig 2.5.0 and Master Branch (ab0ee111). A specially crafted .famos file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.
CVE-2024-31496 1 Fortinet 3 Fortianalyzer, Fortianalyzer Big Data, Fortimanager 2025-01-21 N/A 6.7 MEDIUM
A stack-based buffer overflow vulnerability [CWE-121] in Fortinet FortiManager version 7.4.0 through 7.4.2 and before 7.2.5, FortiAnalyzer version 7.4.0 through 7.4.2 and before 7.2.5 and FortiAnalyzer-BigData 7.4.0 and before 7.2.7 allows a privileged attacker to execute unauthorized code or commands via crafted CLI requests.
CVE-2023-28753 1 Facebook 1 Netconsd 2025-01-21 N/A 9.8 CRITICAL
netconsd prior to v0.2 was vulnerable to an integer overflow in its parse_packet function. A malicious individual could leverage this overflow to create heap memory corruption with attacker controlled data.
CVE-2020-12819 1 Fortinet 1 Fortios 2025-01-21 N/A 5.4 MEDIUM
A heap-based buffer overflow vulnerability in the processing of Link Control Protocol messages in FortiGate versions 5.6.12, 6.0.10, 6.2.4 and 6.4.1 and earlier may allow a remote attacker with valid SSL VPN credentials to crash the SSL VPN daemon by sending a large LCP packet, when tunnel mode is enabled. Arbitrary code execution may be theoretically possible, albeit practically very difficult to achieve in this context
CVE-2020-12820 1 Fortinet 1 Fortios 2025-01-21 N/A 5.4 MEDIUM
Under non-default configuration, a stack-based buffer overflow in FortiOS version 6.0.10 and below, version 5.6.12 and below may allow a remote attacker authenticated to the SSL VPN to crash the FortiClient NAC daemon (fcnacd) and potentially execute arbitrary code via requesting a large FortiClient file name. We are not aware of proof of concept code successfully achieving the latter.
CVE-2022-30114 1 Fastweb 4 Fastgate Gpon Fga2130fwb, Fastgate Gpon Fga2130fwb Firmware, Fastgate Vdsl2 Dga4131fwb and 1 more 2025-01-21 N/A 7.5 HIGH
A heap-based buffer overflow in a network service in Fastweb FASTGate MediaAccess FGA2130FWB, firmware version 18.3.n.0482_FW_230_FGA2130, and DGA4131FWB, firmware version up to 18.3.n.0462_FW_261_DGA4131, allows a remote attacker to reboot the device through a crafted HTTP request, causing DoS.