Total
778 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2024-55196 | 2026-06-17 | N/A | 7.5 HIGH | ||
| Insufficiently Protected Credentials in the Mail Server Configuration in GoPhish v0.12.1 allows an attacker to access cleartext passwords for the configured IMAP and SMTP servers. | |||||
| CVE-2024-55027 | 1 Weintek | 3 Cmt-3072xh2, Cmt-3072xh2 Firmware, Easyweb | 2026-06-17 | N/A | 7.5 HIGH |
| Weintek cMT-3072XH2 easyweb v2.1.53, OS v20231011 was discovered to stroe credentials in plaintext in the component uac_temp.db. | |||||
| CVE-2024-54127 | 2026-06-17 | N/A | N/A | ||
| This vulnerability exists in the TP-Link Archer C50 due to presence of terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the UART shell on the vulnerable device. Successful exploitation of this vulnerability could allow the attacker to obtain Wi-Fi credentials of the targeted system. | |||||
| CVE-2024-53979 | 2026-06-17 | N/A | 8.2 HIGH | ||
| ibm.ibm_zhmc is an Ansible collection for the IBM Z HMC. The Ansible collection "ibm.ibm_zhmc" writes password-like properties in clear text into its log file and into the output returned by some of its Ansible module in the following cases: 1. The 'boot_ftp_password' and 'ssc_master_pw' properties are passed as input to the zhmc_partition Ansible module. 2. The 'ssc_master_pw' and 'zaware_master_pw' properties are passed as input to the zhmc_lpar Ansible module. 3. The 'password' property is passed as input to the zhmc_user Ansible module (just in log file, not in module output). 4. The 'bind_password' property is passed as input to the zhmc_ldap_server_definition Ansible module. These properties appear in the module output only when they were specified in the module input and when creating or updating the corresponding resources. They do not appear in the output when retrieving facts for the corresponding resources. These properties appear in the log file only when the "log_file" module input parameter is used. By default, no log file is created. This issue has been fixed in ibm.ibm_zhmc version 1.9.3. Users are advised to upgrade. There are no known workarounds for this vulnerability. | |||||
| CVE-2024-53865 | 2026-06-17 | N/A | 8.2 HIGH | ||
| zhmcclient is a pure Python client library for the IBM Z HMC Web Services API. In affected versions the Python package "zhmcclient" writes password-like properties in clear text into its HMC and API logs in the following cases: 1. The 'boot-ftp-password' and 'ssc-master-pw' properties when creating or updating a partition in DPM mode, in the zhmcclient API and HMC logs. 2. The 'ssc-master-pw' and 'zaware-master-pw' properties when updating an LPAR in classic mode, in the zhmcclient API and HMC logs. 3. The 'ssc-master-pw' and 'zaware-master-pw' properties when creating or updating an image activation profile in classic mode, in the zhmcclient API and HMC logs. 4. The 'password' property when creating or updating an HMC user, in the zhmcclient API log. 5. The 'bind-password' property when creating or updating an LDAP server definition, in the zhmcclient API and HMC logs. This issue affects only users of the zhmcclient package that have enabled the Python loggers named "zhmcclient.api" (for the API log) or "zhmcclient.hmc" (for the HMC log) and that use the functions listed above. This issue has been fixed in zhmcclient version 1.18.1. Users are advised to upgrade. There are no known workarounds for this vulnerability. | |||||
| CVE-2024-53651 | 2026-06-17 | N/A | 4.6 MEDIUM | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. | |||||
| CVE-2024-52525 | 1 Nextcloud | 1 Nextcloud Server | 2026-06-17 | N/A | 1.8 LOW |
| Nextcloud Server is a self hosted personal cloud system. Under certain conditions the password of a user was stored unencrypted in the session data. The session data is encrypted before being saved in the session storage (Redis or disk), but it would allow a malicious process that gains access to the memory of the PHP process, to get access to the cleartext password of the user. It is recommended that the Nextcloud Server is upgraded to 28.0.12, 29.0.9 or 30.0.2. | |||||
| CVE-2024-52284 | 2026-06-17 | N/A | 7.7 HIGH | ||
| Unauthorized disclosure of sensitive data: Any user with `GET` or `LIST` permissions on `BundleDeployment` resources could retrieve Helm values containing credentials or other secrets. | |||||
| CVE-2024-51993 | 1 Combodo | 1 Itop | 2026-06-17 | N/A | 3.4 LOW |
| Combodo iTop is a web based IT Service Management tool. An attacker accessing a backup file or the database can read some passwords for misconfigured Users. This issue has been addressed in version 3.2.0 and all users are advised to upgrade. Users unable to upgrade are advised to encrypt their backups independently of the iTop application. ### Patches Sanitize parameter ### References N°7631 - Password is stored in clear in the database. | |||||
| CVE-2024-51175 | 2026-06-17 | N/A | 7.5 HIGH | ||
| An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component. | |||||
| CVE-2024-50570 | 1 Fortinet | 1 Forticlient | 2026-06-17 | N/A | 5.0 MEDIUM |
| A Cleartext Storage of Sensitive Information vulnerability [CWE-312] in FortiClientWindows 7.4.0 through 7.4.1, 7.2.0 through 7.2.6, 7.0.0 through 7.0.13 and FortiClientLinux 7.4.0 through 7.4.2, 7.2.0 through 7.2.7, 7.0.0 through 7.0.13 may permit a local authenticated user to retrieve VPN password via memory dump, due to JavaScript's garbage collector | |||||
| CVE-2024-4840 | 2026-06-17 | N/A | 5.5 MEDIUM | ||
| An flaw was found in the OpenStack Platform (RHOSP) director, a toolset for installing and managing a complete RHOSP environment. Plaintext passwords may be stored in log files, which can expose sensitive information to anyone with access to the logs. | |||||
| CVE-2024-4540 | 2026-06-17 | N/A | 7.5 HIGH | ||
| A flaw was found in Keycloak in OAuth 2.0 Pushed Authorization Requests (PAR). Client-provided parameters were found to be included in plain text in the KC_RESTART cookie returned by the authorization server's HTTP response to a `request_uri` authorization request, possibly leading to an information disclosure vulnerability. | |||||
| CVE-2024-4235 | 1 Netgear | 2 Dg834gv5, Dg834gv5 Firmware | 2026-06-17 | 3.3 LOW | 2.7 LOW |
| A vulnerability classified as problematic was found in Netgear DG834Gv5 1.6.01.34. This vulnerability affects unknown code of the component Web Management Interface. The manipulation leads to cleartext storage of sensitive information. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-262126 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | |||||
| CVE-2024-49800 | 1 Ibm | 1 Applinx | 2026-06-17 | N/A | 4.3 MEDIUM |
| IBM ApplinX 11.1 stores sensitive information in cleartext in memory that could be obtained by an authenticated user. | |||||
| CVE-2024-47529 | 1 Openc3 | 1 Cosmos | 2026-06-17 | N/A | 6.5 MEDIUM |
| OpenC3 COSMOS provides the functionality needed to send commands to and receive data from one or more embedded systems. OpenC3 COSMOS stores the password of a user unencrypted in the LocalStorage of a web browser. This makes the user password susceptible to exfiltration via Cross-site scripting (see GHSL-2024-128). This vulnerability is fixed in 5.19.0. This only affects Open Source edition, and not OpenC3 COSMOS Enterprise Edition. | |||||
| CVE-2024-47056 | 2026-06-17 | N/A | 5.1 MEDIUM | ||
| SummaryThis advisory addresses a security vulnerability in Mautic where sensitive .env configuration files may be directly accessible via a web browser. This exposure could lead to the disclosure of sensitive information, including database credentials, API keys, and other critical system configurations. Sensitive Information Disclosure via .env File Exposure: The .env file, which typically contains environment variables and sensitive application configurations, is directly accessible via a web browser due to missing web server configurations that restrict access to such files. This allows an unauthenticated attacker to view the contents of this file by simply navigating to its URL. MitigationUpdate Mautic to the latest Mautic version. By default, Mautic does not use .env files for production data. For Apache users: Ensure your web server is configured to respect .htaccess files. For Nginx users: As Nginx does not inherently support .htaccess files, you must manually add a configuration block to your Nginx server configuration to deny access to .env files. Add the following to your Nginx configuration for the Mautic site: location ~ /\.env { deny all; } After modifying your Nginx configuration, remember to reload or restart your Nginx service for the changes to take effect. | |||||
| CVE-2024-46505 | 2026-06-17 | N/A | 9.1 CRITICAL | ||
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. | |||||
| CVE-2024-46383 | 2026-06-17 | N/A | 2.4 LOW | ||
| Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. | |||||
| CVE-2024-46340 | 1 Tp-link | 2 Tl-wr845n, Tl-wr845n Firmware | 2026-06-17 | N/A | 9.8 CRITICAL |
| TL-WR845N(UN)_V4_201214, TP-Link TL-WR845N(UN)_V4_200909, and TL-WR845N(UN)_V4_190219 was discovered to transmit user credentials in plaintext after executing a factory reset. | |||||
