CVE-2025-25613 1 Fs 2 S3150-8t2f, S3150-8t2f Firmware 2026-06-17 N/A 7.5 HIGH
FS Inc S3150-8T2F 8-Port Gigabit Ethernet L2+ Switch, 8 x Gigabit RJ45, with 2 x 1Gb SFP, Fanless. All versions before 2.2.0D Build 135103 were discovered to transmit cookies for their web based administrative application containing usernames and passwords. These were transmitted in cleartext using simple base64 encoding during every POST request made to the server.
CVE-2025-23291 2026-06-17 N/A 2.4 LOW
NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure.
CVE-2025-23215 2026-06-17 N/A N/A
PMD is an extensible multilanguage static code analyzer. The passphrase for the PMD and PMD Designer release signing keys are included in jar published to Maven Central. The private key itself is not known to have been compromised itself, but given its passphrase is, it must also be considered potentially compromised. As a mitigation, both compromised keys have been revoked so that no future use of the keys are possible. Note, that the published artifacts in Maven Central under the group id net.sourceforge.pmd are not compromised and the signatures are valid.
CVE-2025-23027 2026-06-17 N/A N/A
next-forge is a Next.js project boilerplate for modern web application. The BASEHUB_TOKEN commited in apps/web/.env.example. Users should avoid use of this token and should remove any access it may have in their systems.
CVE-2025-22896 1 Myscada 1 Mypro 2026-06-17 N/A 8.6 HIGH
mySCADA myPRO Manager stores credentials in cleartext, which could allow an attacker to obtain sensitive information.
CVE-2025-21061 1 Samsung 1 Smart Switch 2026-06-17 N/A 7.1 HIGH
Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access sensitive data. User interaction is required for triggering this vulnerability.
CVE-2025-21060 1 Samsung 1 Smart Switch 2026-06-17 N/A 5.5 MEDIUM
Cleartext storage of sensitive information in Smart Switch prior to version 3.7.67.2 allows local attackers to access backup data from applications. User interaction is required for triggering this vulnerability.
CVE-2025-1499 1 Ibm 2 Infosphere Information Server, Infosphere Information Server On Cloud 2026-06-17 N/A 6.5 MEDIUM
IBM InfoSphere Information Server 11.7 stores credential information for database authentication in a cleartext parameter file that could be viewed by an authenticated user.
CVE-2025-14836 1 Zzcms 1 Zzcms 2026-06-17 3.3 LOW 2.7 LOW
A flaw has been found in ZZCMS 2025. Affected by this vulnerability is an unknown functionality of the file /reg/user_save.php of the component User Data Storage Module. This manipulation causes cleartext storage in a file or on disk. Remote exploitation of the attack is possible. The exploit has been published and may be used.
CVE-2025-14377 2026-06-17 N/A N/A
A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024.
CVE-2025-12774 1 Broadcom 1 Sannav 2026-06-17 N/A 7.5 HIGH
A vulnerability in the migration script for Brocade SANnav before 3.0 could allow the collection of database sql queries in the SANnav support save file. An attacker with access to Brocade SANnav supportsave file, could open the file and then obtain sensitive information such as details of database tables and encrypted passwords.
CVE-2025-12772 1 Broadcom 1 Sannav 2026-06-17 N/A 4.9 MEDIUM
Brocade SANnav before 2.4.0b logs the Brocade Fabric OS Switch admin password on the SANnav support save logs. When OOM occurs on a Brocade SANnav server, the call stack trace for the Brocade switch is also collected in the heap dump file which contains this switch password in clear text. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the switch admin password.
CVE-2025-12680 1 Broadcom 1 Sannav 2026-06-17 N/A 4.9 MEDIUM
Brocade SANnav before Brocade SANnav 2.4.0b logs database passwords in clear text in the standby SANnav server, after disaster recovery failover. The vulnerability could allow a remote authenticated attacker with admin privilege able to access the SANnav logs or the supportsave to read the database password.
CVE-2025-12679 1 Broadcom 1 Sannav 2026-06-17 N/A 6.5 MEDIUM
A vulnerability in Brocade SANnav before 2.4.0b prints the Password-Based Encryption (PBE) key in plaintext in the system audit log file. The vulnerability could allow a remote authenticated attacker with access to the audit logs to access the pbe key. Note: The vulnerability is only triggered during a migration and not in a new installation. The system audit logs are accessible only to a privileged user on the server. These audit logs are the local server VM’s audit logs and are not controlled by SANnav. These logs are only visible to the server admin of the host server and are not visible to the SANnav admin or any SANnav user.
CVE-2025-11009 2026-06-17 N/A 5.1 MEDIUM
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials.
CVE-2025-10464 2026-06-17 N/A 6.5 MEDIUM
Insecure Storage of Sensitive Information vulnerability in Birtech Information Technologies Industry and Trade Ltd. Co. Senseway allows Retrieve Embedded Sensitive Data. This issue affects Senseway: through 09022026. NOTE: Because the product was developed using outdated technology, the manufacturer is unable to fix the relevant vulnerabilities. Users of the Sensaway application are advised to contact the manufacturer and review updated products developed with newer technology.
CVE-2025-0418 2026-06-17 N/A N/A
Valmet DNA user passwords in plain text. This practice poses a security risk as attackers who gain access to local project data can read the passwords.
CVE-2025-0142 2026-06-17 N/A 4.3 MEDIUM
Cleartext storage of sensitive information in the Zoom Jenkins Marketplace plugin before version 1.4 may allow an authenticated user to conduct a disclosure of information via network access.
CVE-2025-0123 2026-06-17 N/A N/A
A vulnerability in the Palo Alto Networks PAN-OS® software enables unlicensed administrators to view clear-text data captured using the packet capture feature https://docs.paloaltonetworks.com/pan-os/11-0/pan-os-admin/monitoring/take-packet-captures/take-a-custom-packet-capture in decrypted HTTP/2 data streams traversing network interfaces on the firewall. HTTP/1.1 data streams are not impacted. In normal conditions, decrypted packet captures are available to firewall administrators after they obtain and install a free Decryption Port Mirror license. The license requirement ensures that this feature can only be used after approved personnel purposefully activate the license. For more information, review how to configure decryption port mirroring https://docs.paloaltonetworks.com/network-security/decryption/administration/monitoring-decryption/configure-decryption-port-mirroring . The administrator must obtain network access to the management interface (web, SSH, console, or telnet) and successfully authenticate to exploit this issue. Risk of this issue can be greatly reduced by restricting access to the management interface to only trusted administrators and from only internal IP addresses according to our recommended critical deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . Customer firewall administrators do not have access to the packet capture feature in Cloud NGFW. This feature is available only to authorized Palo Alto Networks personnel permitted to perform troubleshooting. Prisma® Access is not impacted by this vulnerability.
CVE-2024-9991 2026-06-17 N/A N/A
This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device. Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected.