Total
3532 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2017-7562 | 2 Mit, Redhat | 5 Kerberos 5, Enterprise Linux, Enterprise Linux Desktop and 2 more | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
An authentication bypass flaw was found in the way krb5's certauth interface before 1.16.1 handled the validation of client certificates. A remote attacker able to communicate with the KDC could potentially use this flaw to impersonate arbitrary principals under rare and erroneous circumstances. | |||||
CVE-2017-6199 | 1 Sandstorm | 1 Sandstorm | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A remote attacker could bypass the Sandstorm organization restriction before build 0.203 via a comma in an email-address field. | |||||
CVE-2017-6049 | 1 3m | 1 Detcon Sitewatch Gateway | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
Detcon Sitewatch Gateway, all versions without cellular, an attacker can edit settings on the device using a specially crafted URL. | |||||
CVE-2017-5189 | 1 Netiq | 1 Imanager | 2024-11-21 | 5.0 MEDIUM | 4.3 MEDIUM |
NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance. | |||||
CVE-2017-3912 | 1 Mcafee | 1 Application And Change Control | 2024-11-21 | 4.6 MEDIUM | 4.4 MEDIUM |
Bypassing password security vulnerability in McAfee Application and Change Control (MACC) 7.0.1 and 6.2.0 allows authenticated users to perform arbitrary command execution via a command-line utility. | |||||
CVE-2017-3775 | 1 Lenovo | 22 Flex System X240 M5, Flex System X240 M5 Bios, Flex System X280 X6 and 19 more | 2024-11-21 | 6.9 MEDIUM | 6.4 MEDIUM |
Some Lenovo System x server BIOS/UEFI versions, when Secure Boot mode is enabled by a system administrator, do not properly authenticate signed code before booting it. As a result, an attacker with physical access to the system could boot unsigned code. | |||||
CVE-2017-3765 | 2 Ibm, Lenovo | 30 1g L2-7 Slb Switch For Bladecenter, Bladecenter 1\, Bladecenter Layer 2\/3 Copper Ethernet Switch Module and 27 more | 2024-11-21 | 6.2 MEDIUM | 7.0 HIGH |
In Enterprise Networking Operating System (ENOS) in Lenovo and IBM RackSwitch and BladeCenter products, an authentication bypass known as "HP Backdoor" was discovered during a Lenovo security audit in the serial console, Telnet, SSH, and Web interfaces. This bypass mechanism can be accessed when performing local authentication under specific circumstances. If exploited, admin-level access to the switch is granted. | |||||
CVE-2017-2872 | 1 Foscam | 2 C1, C1 Firmware | 2024-11-21 | 9.0 HIGH | 7.2 HIGH |
Insufficient security checks exist in the recovery procedure used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.43. A HTTP request can allow for a user to perform a firmware upgrade using a crafted image. Before any firmware upgrades in this image are flashed to the device, binaries as well as arguments to shell commands contained in the image are executed with elevated privileges. | |||||
CVE-2017-2871 | 1 Foscam | 2 C1, C1 Firmware | 2024-11-21 | 5.8 MEDIUM | 8.8 HIGH |
Insufficient security checks exist in the recovery procedure used by the Foscam C1 Indoor HD Camera running application firmware 2.52.2.43. An attacker who is in the same subnetwork of the camera or has remote administrator access can fully compromise the device by performing a firmware recovery using a custom image. | |||||
CVE-2017-2659 | 1 Dropbear Ssh Project | 1 Dropbear Ssh | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
It was found that dropbear before version 2013.59 with GSSAPI leaks whether given username is valid or invalid. When an invalid username is given, the GSSAPI authentication failure was incorrectly counted towards the maximum allowed number of password attempts. | |||||
CVE-2017-2652 | 1 Jenkins | 1 Distributed Fork | 2024-11-21 | 9.0 HIGH | 8.8 HIGH |
It was found that there were no permission checks performed in the Distributed Fork plugin before and including 1.5.0 for Jenkins that provides the dist-fork CLI command beyond the basic check for Overall/Read permission, allowing anyone with that permission to run arbitrary shell commands on all connected nodes. | |||||
CVE-2017-2638 | 2 Infinispan, Redhat | 2 Infinispan, Jboss Data Grid | 2024-11-21 | 6.4 MEDIUM | 6.5 MEDIUM |
It was found that the REST API in Infinispan before version 9.0.0 did not properly enforce auth constraints. An attacker could use this vulnerability to read or modify data in the default cache or a known cache name. | |||||
CVE-2017-2628 | 2 Haxx, Redhat | 4 Curl, Enterprise Linux Desktop, Enterprise Linux Server and 1 more | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
curl, as shipped in Red Hat Enterprise Linux 6 before version 7.19.7-53, did not correctly backport the fix for CVE-2015-3148 because it did not reflect the fact that the HAVE_GSSAPI define was meanwhile substituted by USE_HTTP_NEGOTIATE. This issue was introduced in RHEL 6.7 and affects RHEL 6 curl only. | |||||
CVE-2017-2604 | 1 Jenkins | 1 Jenkins | 2024-11-21 | 4.0 MEDIUM | 4.3 MEDIUM |
In Jenkins before versions 2.44, 2.32.2 low privilege users were able to act on administrative monitors due to them not being consistently protected by permission checks (SECURITY-371). | |||||
CVE-2017-2297 | 1 Puppet | 1 Puppet Enterprise | 2024-11-21 | 6.0 MEDIUM | 7.5 HIGH |
Puppet Enterprise versions prior to 2016.4.5 and 2017.2.1 did not correctly authenticate users before returning labeled RBAC access tokens. This issue has been fixed in Puppet Enterprise 2016.4.5 and 2017.2.1. This only affects users with labeled tokens, which is not the default for tokens. | |||||
CVE-2017-20133 | 1 Itechscripts | 1 Job Portal Script | 2024-11-21 | N/A | 7.3 HIGH |
A vulnerability, which was classified as critical, was found in Itech Job Portal Script 9.13. This affects an unknown part of the file /admin. The manipulation leads to improper authentication. It is possible to initiate the attack remotely. | |||||
CVE-2017-1783 | 2 Ibm, Netapp | 2 Cognos Analytics, Oncommand Insight | 2024-11-21 | 2.1 LOW | 4.0 MEDIUM |
IBM Cognos Analytics 11.0 could allow a local user to change parameters set from the Cognos Analytics menus without proper authentication. IBM X-Force ID: 136857. | |||||
CVE-2017-18919 | 1 Mattermost | 1 Mattermost Server | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An issue was discovered in Mattermost Server before 3.7.0 and 3.6.3. Attackers can use the API for unauthenticated team creation. | |||||
CVE-2017-18908 | 1 Mattermost | 1 Mattermost Server | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in Mattermost Server before 4.0.0, 3.10.2, and 3.9.2. A password-reset request was sometime sent to an attacker-provided e-mail address. | |||||
CVE-2017-18906 | 1 Mattermost | 1 Mattermost Server | 2024-11-21 | 4.9 MEDIUM | 8.1 HIGH |
An issue was discovered in Mattermost Server before 4.0.0, 3.10.2, and 3.9.2, when Single Sign-On OAuth2 is used. An attacker could claim somebody else's account. |