Vulnerabilities (CVE)

Filtered by CWE-250
Total 266 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2024-6913 2 Microsoft, Perkinelmer 2 Windows, Processplus 2026-06-17 N/A 8.8 HIGH
Execution with unnecessary privileges in PerkinElmer ProcessPlus allows an attacker to spawn a remote shell on the windows system.This issue affects ProcessPlus: through 1.11.6507.0.
CVE-2024-6834 2026-06-17 N/A 9.0 CRITICAL
A vulnerability in APIML Spring Cloud Gateway which leverages user privileges by unexpected signing proxied request by Zowe's client certificate. This allows access to a user to the endpoints requiring an internal client certificate without any credentials. It could lead to managing components in there and allow an attacker to handle the whole communication including user credentials.
CVE-2024-6030 1 Tesla 2 Model S, Model S Firmware 2026-06-17 N/A 7.0 HIGH
Tesla Model S oFono Unnecessary Privileges Sandbox Escape Vulnerability. This vulnerability allows local attackers to escape the sandbox on affected Tesla Model S vehicles. An attacker must first obtain the ability to execute code within the sandbox on the target system in order to exploit this vulnerability. The specific flaw exists within the oFono process. The process allows an attacker to modify interfaces. An attacker can leverage this vulnerability to bypass the iptables network sandbox. Was ZDI-CAN-23200.
CVE-2024-5623 1 Br-automation 1 Industrial Automation Aprol 2026-06-17 N/A 7.8 HIGH
An untrusted search path vulnerability in B&R APROL <= R 4.4-00P3 may be used by an authenticated local attacker to get other users to execute arbitrary code under their privileges.
CVE-2024-5622 1 Br-automation 1 Industrial Automation Aprol 2026-06-17 N/A 7.8 HIGH
An untrusted search path vulnerability in the AprolConfigureCCServices of B&R APROL <= R 4.2.-07P3 and <= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges.
CVE-2024-52799 2026-06-17 N/A 8.2 HIGH
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2024-51722 2026-06-17 N/A 6.4 MEDIUM
A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands.
CVE-2024-50590 2026-06-17 N/A 7.8 HIGH
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2024-49814 1 Ibm 1 Security Verify Access 2026-06-17 N/A 7.8 HIGH
IBM Security Verify Access Appliance 10.0.0 through 10.0.3 could allow a locally authenticated user to increase their privileges due to execution with unnecessary privileges.
CVE-2024-49804 1 Ibm 1 Security Verify Access 2026-06-17 N/A 7.8 HIGH
IBM Security Verify Access Appliance 10.0.0 through 10.0.8 could allow a locally authenticated non-administrative user to escalate their privileges due to unnecessary permissions used to perform certain tasks.
CVE-2024-48837 1 Dell 1 Smartfabric Os10 2026-06-17 N/A 7.8 HIGH
Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution
CVE-2024-48013 1 Dell 1 Smartfabric Os10 2026-06-17 N/A 8.8 HIGH
Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
CVE-2024-47978 1 Dell 1 Nativeedge Orchestrator 2026-06-17 N/A 7.8 HIGH
Dell NativeEdge, version(s) 2.1.0.0, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Elevation of privileges.
CVE-2024-47903 1 Siemens 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware 2026-06-17 N/A 5.8 MEDIUM
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server's DocumentRoot directory.
CVE-2024-47120 2 Ibm, Linux 2 Security Verify Information Queue, Linux Kernel 2026-06-17 N/A 6.4 MEDIUM
IBM Security Verify Information Queue 10.0.5, 10.0.6, 10.0.7, and 10.0.8 could allow a privileged user to escalate their privileges and attack surface on the host due to the containers running with unnecessary privileges.
CVE-2024-45034 1 Apache 1 Airflow 2026-06-17 N/A 8.8 HIGH
Apache Airflow versions before 2.10.1 have a vulnerability that allows DAG authors to add local settings to the DAG folder and get it executed by the scheduler, where the scheduler is not supposed to execute code submitted by the DAG author. Users are advised to upgrade to version 2.10.1 or later, which has fixed the vulnerability.
CVE-2024-43655 2026-06-17 N/A N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-06-17 N/A 8.8 HIGH
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-06-17 N/A 8.8 HIGH
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43652 2026-06-17 N/A 8.8 HIGH
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.