Total
194 CVE
| CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
|---|---|---|---|---|---|
| CVE-2019-10143 | 3 Fedoraproject, Freeradius, Redhat | 3 Fedora, Freeradius, Enterprise Linux | 2024-11-21 | 6.9 MEDIUM | 7.0 HIGH |
| It was discovered freeradius up to and including version 3.0.19 does not correctly configure logrotate, allowing a local attacker who already has control of the radiusd user to escalate his privileges to root, by tricking logrotate into writing a radiusd-writable file to a directory normally inaccessible by the radiusd user. NOTE: the upstream software maintainer has stated "there is simply no way for anyone to gain privileges through this alleged issue." | |||||
| CVE-2018-10892 | 4 Docker, Mobyproject, Opensuse and 1 more | 6 Docker, Moby, Leap and 3 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
| The default OCI linux spec in oci/defaults{_linux}.go in Docker/Moby from 1.11 to current does not block /proc/acpi pathnames. The flaw allows an attacker to modify host's hardware like enabling/disabling bluetooth or turning up/down keyboard brightness. | |||||
| CVE-2018-10872 | 1 Redhat | 4 Enterprise Linux, Enterprise Linux Desktop, Enterprise Linux Server and 1 more | 2024-11-21 | 4.9 MEDIUM | 6.5 MEDIUM |
| A flaw was found in the way the Linux kernel handled exceptions delivered after a stack switch operation via Mov SS or Pop SS instructions. During the stack switch operation, processor does not deliver interrupts and exceptions, they are delivered once the first instruction after the stack switch is executed. An unprivileged system user could use this flaw to crash the system kernel resulting in DoS. This CVE-2018-10872 was assigned due to regression of CVE-2018-8897 in Red Hat Enterprise Linux 6.10 GA kernel. No other versions are affected by this CVE. | |||||
| CVE-2024-11075 | 2024-11-19 | N/A | 8.8 HIGH | ||
| A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system. | |||||
| CVE-2024-48837 | 1 Dell | 1 Smartfabric Os10 | 2024-11-18 | N/A | 7.8 HIGH |
| Dell SmartFabric OS10 Software, version(s) 10.5.6.x, 10.5.5.x, 10.5.4.x, 10.5.3.x, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Command execution | |||||
| CVE-2024-8781 | 2024-11-18 | N/A | N/A | ||
| Execution with Unnecessary Privileges, : Improper Protection of Alternate Path vulnerability in TR7 Application Security Platform (ASP) allows Privilege Escalation, -Privilege Abuse.This issue affects Application Security Platform (ASP): v1.4.25.188. | |||||
| CVE-2024-51722 | 2024-11-13 | N/A | 6.4 MEDIUM | ||
| A local privilege escalation vulnerability in the SecuSUITE Server (System Configuration) of SecuSUITE versions 5.0.420 and earlier could allow a successful attacker that had gained control of code running under one of the system accounts listed in the configuration file to potentially issue privileged script commands. | |||||
| CVE-2024-20420 | 1 Cisco | 4 Ata 191, Ata 191 Firmware, Ata 192 and 1 more | 2024-10-31 | N/A | 8.8 HIGH |
| A vulnerability in the web-based management interface of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an authenticated, remote attacker with low privileges to run commands as an Admin user. This vulnerability is due to incorrect authorization verification by the HTTP server. An attacker could exploit this vulnerability by sending a malicious request to the web-based management interface. A successful exploit could allow the attacker to run commands as the Admin user. | |||||
| CVE-2024-47903 | 1 Siemens | 3 Intermesh 7177 Hybrid 2.0 Subscriber, Intermesh 7707 Fire Subscriber, Intermesh 7707 Fire Subscriber Firmware | 2024-10-30 | N/A | 9.1 CRITICAL |
| A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices allows to write arbitrary files to the web server's DocumentRoot directory. | |||||
| CVE-2024-8903 | 2024-09-26 | N/A | 4.7 MEDIUM | ||
| Local active protection service settings manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Cyber Protect Cloud Agent (Windows, macOS) before build 38565. | |||||
| CVE-2024-8767 | 2024-09-20 | N/A | 9.9 CRITICAL | ||
| Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147. | |||||
| CVE-2024-5622 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-09-13 | N/A | 7.8 HIGH |
| An untrusted search path vulnerability in the AprolConfigureCCServices of B&R APROL <= R 4.2.-07P3 and <= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges. | |||||
| CVE-2024-5623 | 1 Br-automation | 1 Industrial Automation Aprol | 2024-09-13 | N/A | 7.8 HIGH |
| An untrusted search path vulnerability in B&R APROL <= R 4.4-00P3 may be used by an authenticated local attacker to get other users to execute arbitrary code under their privileges. | |||||
| CVE-2024-36398 | 1 Siemens | 1 Sinec Nms | 2024-08-14 | N/A | 7.8 HIGH |
| A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application executes a subset of its services as `NT AUTHORITY\SYSTEM`. This could allow a local attacker to execute operating system commands with elevated privileges. | |||||
