Total
8056 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-7312 | 1 Primx | 3 Zed, Zedmail, Zonecentral | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
Limited plaintext disclosure exists in PRIMX Zed Entreprise for Windows before 6.1.2240, Zed Entreprise for Windows (ANSSI qualification submission) before 6.1.2150, Zed Entreprise for Mac before 2.0.199, Zed Entreprise for Linux before 2.0.199, Zed Pro for Windows before 1.0.195, Zed Pro for Mac before 1.0.199, Zed Pro for Linux before 1.0.199, Zed Free for Windows before 1.0.195, Zed Free for Mac before 1.0.199, and Zed Free for Linux before 1.0.199. Analyzing a Zed container can lead to the disclosure of plaintext content of very small files (a few bytes) stored into it. | |||||
CVE-2019-7259 | 1 Nortekcontrol | 4 Linear Emerge Elite, Linear Emerge Elite Firmware, Linear Emerge Essential and 1 more | 2024-11-21 | 4.0 MEDIUM | 8.8 HIGH |
Linear eMerge E3-Series devices allow Authorization Bypass with Information Disclosure. | |||||
CVE-2019-6852 | 1 Schneider-electric | 20 140 Cpu6x, 140 Cpu6x Firmware, 140 Noc 77101 and 17 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-200: Information Exposure vulnerability exists in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network. | |||||
CVE-2019-6851 | 1 Schneider-electric | 46 Modicon M340, Modicon M340 Firmware, Modicon M580 and 43 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-538: File and Directory Information Exposure vulnerability exists in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum (all firmware versions), which could cause the disclosure of information from the controller when using TFTP protocol. | |||||
CVE-2019-6850 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when reading specific registers with the REST API of the controller/communication module. | |||||
CVE-2019-6849 | 1 Schneider-electric | 6 Modicon Bmenoc 0311, Modicon Bmenoc 0311 Firmware, Modicon Bmenoc 0321 and 3 more | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-200: Information Exposure vulnerability exists in Modicon M580, Modicon BMENOC 0311, and Modicon BMENOC 0321, which could cause the disclosure of sensitive information when using specific Modbus services provided by the REST API of the controller/communication module. | |||||
CVE-2019-6700 | 1 Fortinet | 1 Fortisiem | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
An information exposure vulnerability in the external authentication profile form of FortiSIEM 5.2.2 and earlier may allow an authenticated attacker to retrieve the external authentication password via the HTML source code. | |||||
CVE-2019-6331 | 1 Hp | 1 Samsung Mobile Print | 2024-11-21 | 2.1 LOW | 3.3 LOW |
An issue was found in Samsung Mobile Print (Android) versions prior to 4.08.007. A potential security vulnerability caused by incomplete obfuscation of application configuration information. | |||||
CVE-2019-6206 | 1 Apple | 1 Iphone Os | 2024-11-21 | 5.0 MEDIUM | 9.8 CRITICAL |
An issue existed with autofill resuming after it was canceled. The issue was addressed with improved state management. This issue is fixed in iOS 12.1.3. Password autofill may fill in passwords after they were manually cleared. | |||||
CVE-2019-6193 | 1 Lenovo | 1 Xclarity Administrator | 2024-11-21 | 5.0 MEDIUM | 7.5 HIGH |
An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes. | |||||
CVE-2019-6177 | 1 Lenovo | 1 Solution Center | 2024-11-21 | 7.5 HIGH | 9.8 CRITICAL |
A vulnerability reported in Lenovo Solution Center version 03.12.003, which is no longer supported, could allow log files to be written to non-standard locations, potentially leading to privilege escalation. Lenovo ended support for Lenovo Solution Center and recommended that customers migrate to Lenovo Vantage or Lenovo Diagnostics in April 2018. | |||||
CVE-2019-5884 | 1 Std42 | 1 Elfinder | 2024-11-21 | 4.3 MEDIUM | 5.9 MEDIUM |
php/elFinder.class.php in elFinder before 2.1.45 leaks information if PHP's curl extension is enabled and safe_mode or open_basedir is not set. | |||||
CVE-2019-5880 | 1 Google | 1 Chrome | 2024-11-21 | 4.3 MEDIUM | 7.4 HIGH |
Insufficient policy enforcement in Blink in Google Chrome prior to 77.0.3865.75 allowed a remote attacker to leak cross-origin data via a crafted HTML page. | |||||
CVE-2019-5640 | 1 Rapid7 | 1 Nexpose | 2024-11-21 | 5.0 MEDIUM | 3.3 LOW |
Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user | |||||
CVE-2019-5601 | 1 Freebsd | 1 Freebsd | 2024-11-21 | 4.0 MEDIUM | 6.5 MEDIUM |
In FreeBSD 12.0-STABLE before r347474, 12.0-RELEASE before 12.0-RELEASE-p7, 11.2-STABLE before r347475, and 11.2-RELEASE before 11.2-RELEASE-p11, a bug in the FFS implementation causes up to three bytes of kernel stack memory to be written to disk as uninitialized directory entry padding. | |||||
CVE-2019-5534 | 1 Vmware | 1 Vcenter Server | 2024-11-21 | 4.0 MEDIUM | 7.7 HIGH |
VMware vCenter Server (6.7.x prior to 6.7 U3, 6.5 prior to 6.5 U3 and 6.0 prior to 6.0 U3j) contains an information disclosure vulnerability where Virtual Machines deployed from an OVF could expose login information via the virtual machine's vAppConfig properties. A malicious actor with access to query the vAppConfig properties of a virtual machine deployed from an OVF may be able to view the credentials used to deploy the OVF (typically the root account of the virtual machine). | |||||
CVE-2019-5463 | 1 Gitlab | 1 Gitlab | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An authorization issue was discovered in the GitLab CE/EE CI badge images endpoint which could result in disclosure of the build status. This vulnerability was addressed in 12.1.2, 12.0.4, and 11.11.6. | |||||
CVE-2019-5437 | 1 Harpjs | 1 Harp | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
Information exposure through the directory listing in npm's harp module allows to access files that are supposed to be ignored according to the harp server rules.Vulnerable versions are <= 0.29.0 and no fix was applied to our knowledge. | |||||
CVE-2019-5073 | 1 Wago | 4 Pfc 100, Pfc 100 Firmware, Pfc 200 and 1 more | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An exploitable information exposure vulnerability exists in the iocheckd service "I/O-Check" functionality of WAGO PFC200 Firmware versions 03.01.07(13) and 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause an external tool to fail, resulting in uninitialized stack data to be copied to the response packet buffer. An attacker can send unauthenticated packets to trigger this vulnerability. | |||||
CVE-2019-5017 | 2 Kcodes, Netgear | 3 Netusb.ko, R8000, R8000 Firmware | 2024-11-21 | 5.0 MEDIUM | 5.3 MEDIUM |
An exploitable information disclosure vulnerability exists in the KCodes NetUSB.ko kernel module that enables the ReadySHARE Printer functionality of at least two NETGEAR Nighthawk Routers and potentially several other vendors/products. An unauthenticated, remote attacker can craft and send a packet containing an opcode that will trigger the kernel module to return several addresses. One of which can be used to calculate the dynamic base address of the module for further exploitation. |