Export limit exceeded: 424857 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 29277 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (29277 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-3854 | 2026-04-15 | 8 High | ||
| A vulnerability, which was classified as critical, was found in H3C GR-3000AX up to V100R006. Affected is the function EnableIpv6/UpdateWanModeMulti/UpdateIpv6Params/EditWlanMacList/Edit_List_SSID of the file /goform/aspForm of the component HTTP POST Request Handler. The manipulation of the argument param leads to buffer overflow. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. Other functions might be affected as well. | ||||
| CVE-2023-6095 | 2026-04-15 | 8.9 High | ||
| Vladimir Kononovich, a Security Researcher has found a flaw that allows for a remote code execution on the DVR. An attacker could inject malicious HTTP headers into request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds. | ||||
| CVE-2023-6116 | 1 Hanwhavision | 1 Xrn-420s | 2026-04-15 | 8.9 High |
| Team ENVY, a Security Research TEAM has found a flaw that allows for a remote code execution on the camera. An attacker could inject malicious into http request packets to execute arbitrary code. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds. | ||||
| CVE-2024-22040 | 1 Siemens | 14 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 11 more | 2026-04-15 | 7.5 High |
| A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems insufficiently validates HMAC values which might result in a buffer overread. This could allow an unauthenticated remote attacker to crash the network service. | ||||
| CVE-2025-24328 | 2026-04-15 | 4.2 Medium | ||
| Sending a crafted SOAP "set" operation message within the Mobile Network Operator (MNO) internal Radio Access Network (RAN) management network can cause Nokia Single RAN baseband OAM service component restart with software versions earlier than release 24R1-SR 1.0 MP. This issue has been corrected to release 24R1-SR 1.0 MP and later. The OAM service component restarts automatically after the stack overflow without causing a base station restart or network service degradation, and without leaving any permanent impact on the Nokia Single RAN baseband OAM service. | ||||
| CVE-2025-24335 | 2026-04-15 | 2 Low | ||
| Nokia Single RAN baseband software versions earlier than 24R1-SR 2.1 MP contain a SOAP message input validation flaw, which in theory could potentially be used for causing resource exhaustion in the Single RAN baseband OAM service. No practical exploit has been detected for this flaw. However, the issue has been corrected starting from release 24R1-SR 2.1 MP by adding sufficient input validation for received SOAP requests, effectively mitigating the reported issue. | ||||
| CVE-2025-24802 | 2026-04-15 | 8.6 High | ||
| Plonky2 is a SNARK implementation based on techniques from PLONK and FRI. Lookup tables, whose length is not divisible by 26 = floor(num_routed_wires / 3) always include the 0 -> 0 input-output pair. Thus a malicious prover can always prove that f(0) = 0 for any lookup table f (unless its length happens to be divisible by 26). The cause of problem is that the LookupTableGate-s are padded with zeros. A workaround from the user side is to extend the table (by repeating some entries) so that its length becomes divisible by 26. This vulnerability is fixed in 1.0.1. | ||||
| CVE-2023-6948 | 2026-04-15 | 3 Low | ||
| A Buffer Copy without Checking Size of Input issue affecting the v2_sdk_service running on a set of DJI drone devices on the port 10000 could allow an attacker to cause a crash of the service through a crafted payload triggering a missing input size check in the sdk_printf function implemented in the libv2_sdk.so library used by the dji_vtwo_sdk binary implementing the service, compromising it in a term of availability and producing a denial-of-service attack. Affected models are Mavic 3 Pro until v01.01.0300, Mavic 3 until v01.00.1200, Mavic 3 Classic until v01.00.0500, Mavic 3 Enterprise until v07.01.10.03, Matrice 300 until v57.00.01.00, Matrice M30 until v07.01.0022 and Mini 3 Pro until v01.00.0620. | ||||
| CVE-2023-6950 | 2026-04-15 | 3 Low | ||
| An Improper Input Validation vulnerability affecting the FTP service running on the DJI Mavic Mini 3 Pro could allow an attacker to craft a malicious packet containing a malformed path provided to the FTP SIZE command that leads to a denial-of-service attack of the FTP service itself. | ||||
| CVE-2024-52544 | 1 Lorextechnology | 1 W461asc-e Firmware | 2026-04-15 | 9.8 Critical |
| An unauthenticated attacker can trigger a stack based buffer overflow in the DP Service (TCP port 3500). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111. | ||||
| CVE-2024-52545 | 1 Lorextechnology | 1 W461asc-e Firmware | 2026-04-15 | 6.5 Medium |
| An unauthenticated attacker can perform an out of bounds heap read in the IQ Service (TCP port 9876). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111. | ||||
| CVE-2025-32412 | 2026-04-15 | 7.8 High | ||
| Fuji Electric Smart Editor is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2024-7013 | 1 Panasonic | 1 Control Fpwin Pro | 2026-04-15 | 7.8 High |
| Stack-based buffer overflow in Control FPWIN Pro version 7.7.2.0 and all previous versions may allow attackers to execute arbitrary code via a specially crafted project file. | ||||
| CVE-2024-7011 | 2026-04-15 | 6.5 Medium | ||
| Sharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service. | ||||
| CVE-2024-11168 | 2 Python Software Foundation, Redhat | 2 Cpython, Enterprise Linux | 2026-04-15 | 3.7 Low |
| The urllib.parse.urlsplit() and urlparse() functions improperly validated bracketed hosts (`[]`), allowing hosts that weren't IPv6 or IPvFuture. This behavior was not conformant to RFC 3986 and potentially enabled SSRF if a URL is processed by more than one URL parser. | ||||
| CVE-2024-52547 | 1 Lorextechnology | 1 W461asc-e Firmware | 2026-04-15 | 7.2 High |
| An authenticated attacker can trigger a stack based buffer overflow in the DHIP Service (TCP port 80). This vulnerability has been resolved in firmware version 2.800.0000000.8.R.20241111. | ||||
| CVE-2024-11217 | 1 Redhat | 1 Openshift | 2026-04-15 | 4.9 Medium |
| A vulnerability was found in the OAuth-server. OAuth-server logs the OAuth2 client secret when the logLevel is Debug higher for OIDC/GitHub/GitLab/Google IDPs login options. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||
| CVE-2025-35998 | 1 Intel | 1 Intel Platforms | 2026-04-15 | 7.9 High |
| Missing protection mechanism for alternate hardware interface in the Intel(R) Quick Assist Technology for some Intel(R) Platforms within Ring 0: Kernel may allow an escalation of privilege. System software adversary with a privileged user combined with a low complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are present with special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (none) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts. | ||||
| CVE-2024-6873 | 1 Clickhouse | 1 Clickhouse | 2026-04-15 | 8.1 High |
| It is possible to crash or redirect the execution flow of the ClickHouse server process from an unauthenticated vector by sending a specially crafted request to the ClickHouse server native interface. This redirection is limited to what is available within a 256-byte range of memory at the time of execution, and no known remote code execution (RCE) code has been produced or exploited. Fixes have been merged to all currently supported version of ClickHouse. If you are maintaining your own forked version of ClickHouse or using an older version and cannot upgrade, the fix for this vulnerability can be found in this commit https://github.com/ClickHouse/ClickHouse/pull/64024 . | ||||