Export limit exceeded: 18136 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (18136 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-67859 1 Linrunner 1 Tlp 2026-04-15 N/A
A Improper Authentication vulnerability in TLP allows local users to arbitrarily control the power profile in use as well as the daemon’s log settings.This issue affects TLP: from 1.9 before 1.9.1.
CVE-2025-11901 1 Asus 13 B460, B560, B660 and 10 more 2026-04-15 N/A
An uncontrolled resource consumption vulnerability affects certain ASUS motherboards using Intel B460, B560, B660, B760, H410, H510, H610, H470, Z590, Z690, Z790, W480, W680 series chipsets. Exploitation requires physical access to internal expansion slots to install a specially crafted device and supporting software utility, and may lead to uncontrolled resource consumption that increases the risk of unauthorized direct memory access (DMA). Refer to the 'Security Update for UEFI firmware' section on the ASUS Security Advisory for more information.
CVE-2025-10755 1 Selleo 1 Mentingo 2026-04-15 6.3 Medium
A vulnerability was detected in Selleo Mentingo 2025.08.27. The impacted element is an unknown function of the component Content-Type Handler. The manipulation of the argument userAvatar results in unrestricted upload. The attack may be performed from remote. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11130 2 Apple, Ihongren 2 Macos, Pptp-vpn 2026-04-15 8.4 High
A weakness has been identified in iHongRen pptp-vpn 1.0/1.0.1 on macOS. This issue affects the function shouldAcceptNewConnection of the file HelpTool/HelperTool.m of the component XPC Service. This manipulation causes missing authentication. The attack can only be executed locally. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-42048 2026-04-15 6.5 Medium
OpenOrange Business Framework version 1.15.5 installs to a directory with overly permissive access control, allowing all authenticated users to write to the installation path. In combination with the application's behavior of loading DLLs from this location, this allows for DLL hijacking and may result in arbitrary code execution and privilege escalation.
CVE-2025-11256 2 Kognetiks, Wordpress 2 Chatbot, Wordpress 2026-04-15 5.3 Medium
The Kognetiks Chatbot plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on several functions in all versions up to, and including, 2.3.5. This makes it possible for unauthenticated attackers to upload limited safe files and erase conversations.
CVE-2025-11321 1 Zhuimengshaonian 1 Wisdom-education 2026-04-15 4.3 Medium
A vulnerability was detected in zhuimengshaonian wisdom-education up to 1.0.4. The affected element is an unknown function of the file src/main/java/com/education/api/controller/student/WrongBookController.java. Performing manipulation of the argument subjectId results in authorization bypass. The attack can be initiated remotely. The exploit is now public and may be used.
CVE-2025-8265 1 299ko 1 Cms 2026-04-15 4.7 Medium
A vulnerability classified as critical has been found in 299Ko CMS 2.0.0. This affects an unknown part of the file /admin/filemanager/view of the component File Management. The manipulation leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-11852 1 Apeman 1 Apeman 2026-04-15 5.3 Medium
A vulnerability was found in Apeman ID71 218.53.203.117. The impacted element is an unknown function of the file /onvif/device_service of the component ONVIF Service. Performing manipulation results in missing authentication. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-1259 2026-04-15 7.7 High
On affected platforms running Arista EOS with OpenConfig configured, a gNOI request can be run when it should have been rejected. This issue can result in users retrieving data that should not have been available
CVE-2025-1260 1 Arista 1 Eos 2026-04-15 9.1 Critical
On affected platforms running Arista EOS with OpenConfig configured, a gNOI request can be run when it should have been rejected. This issue can result in unexpected configuration/operations being applied to the switch.
CVE-2025-12623 1 Fushengqian 1 Fuint 2026-04-15 3.1 Low
A vulnerability was identified in fushengqian fuint up to 41e26be8a2c609413a0feaa69bdad33a71ae8032. Affected by this issue is some unknown functionality of the file fuint-application/src/main/java/com/fuint/module/clientApi/controller/ClientSignController.java of the component Authentication Token Handler. Such manipulation leads to authorization bypass. The attack may be launched remotely. Attacks of this nature are highly complex. The exploitation is known to be difficult. The exploit is publicly available and might be used. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
CVE-2025-13427 1 Google 1 Cloud Dialogflow Cx 2026-04-15 N/A
An authentication bypass vulnerability in Google Cloud Dialogflow CX Messenger allowed unauthenticated users to interact with restricted chat agents, gaining access to the agents' knowledge and the ability to trigger their intents, by manipulating initialization parameters or crafting specific API requests. All versions after August 20th, 2025 have been updated to protect from this vulnerability. No user action is required for this.
CVE-2025-9313 1 Mmedica 1 Mmedica 2026-04-15 N/A
An unauthenticated user can connect to a publicly accessible database using arbitrary credentials. The system grants full access to the database by leveraging a previously authenticated connection through a "mmBackup" application. This flaw allows attackers to bypass authentication mechanisms and gain unauthorized access to database with sensitive data. This issue affects Asseco mMedica in versions before 11.9.5.
CVE-2025-14095 2 Microsoft, Radiometer 7 Windows, Abl800 Basic Analyzer, Abl800 Flex Analyzer and 4 more 2026-04-15 5.7 Medium
A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.  Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication.                                                                                                                                                                                        Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.
CVE-2025-14097 1 Radiometer 5 Abl800 Basic Analyzer, Abl800 Flex Analyzer, Abl90 Flex Analyzer and 2 more 2026-04-15 7.2 High
A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                      Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.
CVE-2025-67603 2026-04-15 7.3 High
A Improper Authorization vulnerability in Foomuuri llows arbitrary users to influence the firewall configuration.This issue affects Foomuuri: from ? before 0.31.
CVE-2025-21618 2026-04-15 7.5 High
NiceGUI is an easy-to-use, Python-based UI framework. Prior to 2.9.1, authenticating with NiceGUI logged in the user for all browsers, including browsers in incognito mode. This vulnerability is fixed in 2.9.1.
CVE-2025-24784 2026-04-15 4.3 Medium
kubewarden-controller is a Kubernetes controller that allows you to dynamically register Kubewarden admission policies. The policy group feature, added to by the 1.17.0 release. By being namespaced, the AdmissionPolicyGroup has a well constrained impact on cluster resources. Hence, it’s considered safe to allow non-admin users to create and manage these resources in the namespaces they own. Kubewarden policies can be allowed to query the Kubernetes API at evaluation time; these types of policies are called “context aware“. Context aware policies can perform list and get operations against a Kubernetes cluster. The queries are done using the ServiceAccount of the Policy Server instance that hosts the policy. That means that access to the cluster is determined by the RBAC rules that apply to that ServiceAccount. The AdmissionPolicyGroup CRD allowed the deployment of context aware policies. This could allow an attacker to obtain information about resources that are out of their reach, by leveraging a higher access to the cluster granted to the ServiceAccount token used to run the policy. The impact of this vulnerability depends on the privileges that have been granted to the ServiceAccount used to run the Policy Server and assumes that users are using the recommended best practices of keeping the Policy Server's ServiceAccount least privileged. By default, the Kubewarden helm chart grants access to the following resources (cluster wide) only: Namespace, Pod, Deployment and Ingress. This vulnerability is fixed in 1.21.0.
CVE-2025-63422 1 Each Italy 1 Wireless Mini Router 2026-04-15 7.5 High
Incorrect access control in the Web management interface in Each Italy Wireless Mini Router WIRELESS-N 300M v28K.MiniRouter.20190211 allows attackers to arbitrarily change the administrator username and password via sending a crafted GET request.