Export limit exceeded: 24290 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (24290 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-38533 1 Matter-labs 1 Era-compiler-vyper 2026-04-15 6.5 Medium
ZKsync Era is a layer 2 rollup that uses zero-knowledge proofs to scale Ethereum. There is possible invalid stack access due to the addresses used to access the stack not properly being converted to cells. This issue has been patched in version 1.5.0.
CVE-2024-39251 1 Thunderobot 1 Control Center 2026-04-15 10 Critical
An issue in the component ControlCenter.sys/ControlCenter64.sys of ThundeRobot Control Center v2.0.0.10 allows attackers to access sensitive information, execute arbitrary code, or escalate privileges via sending crafted IOCTL requests.
CVE-2024-48895 1 Rakuten 1 Turbo 5g Firmware 2026-04-15 8.8 High
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote authenticated attacker may execute an arbitrary OS command.
CVE-2024-48459 1 Tenda 1 Ax2 Pro Firmware 2026-04-15 7.3 High
A command execution vulnerability exists in the AX2 Pro home router produced by Shenzhen Tenda Technology Co., Ltd. (Jixiang Tenda) v.DI_7003G-19.12.24A1V16.03.29.50;V16.03.29.50;V16.03.29.50. An attacker can exploit this vulnerability by constructing a malicious payload to execute commands and further obtain shell access to the router's file system with the highest privileges.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2021-47774 1 Kingdia 1 Cd Extractor 2026-04-15 9.8 Critical
Kingdia CD Extractor 3.0.2 contains a buffer overflow vulnerability in the registration name field that allows attackers to execute arbitrary code. Attackers can craft a malicious payload exceeding 256 bytes to overwrite Structured Exception Handler and gain remote code execution through a bind shell.
CVE-2021-47705 1 Commax 1 Ums Client Activex Control 2026-04-15 N/A
COMMAX UMS Client ActiveX Control 1.7.0.2 contains a heap-based buffer overflow vulnerability that allows attackers to execute arbitrary code by providing excessively long string arrays through multiple functions. Attackers can exploit improper boundary validation in CNC_Ctrl.dll to cause heap corruption and potentially gain system-level access.
CVE-2020-37031 1 Ashkon 1 Simple Startup Manager 2026-04-15 8.4 High
Simple Startup Manager 1.17 contains a local buffer overflow vulnerability that allows attackers to execute arbitrary code by overwriting memory through the 'File' input parameter. Attackers can craft a malicious payload with 268 bytes to trigger code execution, bypassing DEP and overwriting memory addresses to launch calc.exe.
CVE-2020-37027 1 Midgetspy 1 Sickbeard 2026-04-15 9.8 Critical
Sickbeard alpha contains a remote command injection vulnerability that allows unauthenticated attackers to execute arbitrary commands through the extra scripts configuration. Attackers can set malicious commands in the extra scripts field and trigger processing to execute remote code on the vulnerable Sickbeard installation.
CVE-2021-47747 2026-04-15 8.8 High
meterN 1.2.3 contains an authenticated remote code execution vulnerability in admin_meter2.php and admin_indicator2.php scripts. Attackers can exploit the 'COMMANDx' and 'LIVECOMMANDx' POST parameters to execute arbitrary system commands with administrative privileges.
CVE-2021-47775 1 Litexmedia 1 Youtube Video Grabber 2026-04-15 8.4 High
YouTube Video Grabber, now referred to as YouTube Downloader, 1.9.9.1 contains a buffer overflow vulnerability that allows attackers to execute arbitrary code by overwriting the Structured Exception Handler. Attackers can craft a malicious payload of 712 bytes with SEH manipulation to trigger a bind shell connection on a specified local port.
CVE-2025-48047 2026-04-15 N/A
An authenticated user can perform command injection via unsanitized input to the NetFax Server’s ping functionality via the /test.php endpoint.
CVE-2025-5898 1 Gnu 1 Pspp 2026-04-15 5.3 Medium
A vulnerability classified as critical has been found in GNU PSPP 82fb509fb2fedd33e7ac0c46ca99e108bb3bdffb. Affected is the function parse_variables_option of the file utilities/pspp-convert.c. The manipulation leads to out-of-bounds write. The attack needs to be approached locally. The exploit has been disclosed to the public and may be used.
CVE-2020-37012 1 Ammarfaizi2 1 Tea Latex 2026-04-15 9.8 Critical
Tea LaTex 1.0 contains a remote code execution vulnerability that allows unauthenticated attackers to execute arbitrary shell commands through the /api.php endpoint. Attackers can craft a malicious LaTeX payload with shell commands that are executed when processed by the application's tex2png API action.