CVE-2026-46747

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application does not properly sanitize path input in the `GET /api/sftp/uploadFiles` endpoint used for directory listing. This allows path traversal through crafted input, enabling access to unintended file system locations.
References
Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:sinec_ins:*:-:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_3:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_4:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_5:*:*:*:*:*:*

History

12 Jun 2026, 15:28

Type Values Removed Values Added
CPE cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_5:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_3:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_4:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:*:-:*:*:*:*:*:*
cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*
First Time Siemens
Siemens sinec Ins
References () https://cert-portal.siemens.com/productcert/html/ssa-860189.html - () https://cert-portal.siemens.com/productcert/html/ssa-860189.html - Vendor Advisory

09 Jun 2026, 10:16

Type Values Removed Values Added
New CVE

Information

Published : 2026-06-09 10:16

Updated : 2026-06-17 10:53


NVD link : CVE-2026-46747

Mitre link : CVE-2026-46747

CVE.ORG link : CVE-2026-46747


JSON object : View

Products Affected

siemens

  • sinec_ins
CWE
CWE-26

Path Traversal: '/dir/../filename'