FlexRIC v2.0.0 crashes when receiving a duplicate E2_SETUP_REQUEST from the same or spoofed E2 Node. The iApp registry enforces node ID uniqueness via assert() rather than graceful rejection. A remote unauthenticated attacker can crash the iApp process (port 36421) by sending two E2_SETUP_REQUESTs with the same E2 node configuration, triggering SIGABRT.
References
Configurations
No configuration.
History
01 Jun 2026, 21:16
| Type | Values Removed | Values Added |
|---|---|---|
| CVSS |
v2 : v3 : |
v2 : unknown
v3 : 7.5 |
| CWE | CWE-617 |
01 Jun 2026, 17:16
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-06-01 17:16
Updated : 2026-06-01 21:16
NVD link : CVE-2026-37224
Mitre link : CVE-2026-37224
CVE.ORG link : CVE-2026-37224
JSON object : View
Products Affected
No product.
CWE
CWE-617
Reachable Assertion