The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
CVSS
No CVSS.
References
Configurations
No configuration.
History
15 Jun 2026, 14:16
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
15 Jun 2026, 12:16
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-06-15 12:16
Updated : 2026-06-17 10:38
NVD link : CVE-2026-34021
Mitre link : CVE-2026-34021
CVE.ORG link : CVE-2026-34021
JSON object : View
Products Affected
No product.
CWE
CWE-294
Authentication Bypass by Capture-replay