A vulnerability was found in kronosnet's (version <=1.34) cryptographic configuration management. The framework does not correctly zero-out or wipe sensitive memory segments after executing changes to its cryptographic configuration. This omission leaves raw encryption keys resident in memory after the associated structures are freed. A local attacker capable of leveraging memory disclosure techniques could exploit this flaw to retrieve the active encryption key, allowing them to decrypt cluster network communications or inject malicious packets to cause severe high-availability cluster instability.
References
Configurations
No configuration.
History
21 Jul 2026, 06:16
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-07-21 06:16
Updated : 2026-07-23 15:16
NVD link : CVE-2026-15811
Mitre link : CVE-2026-15811
CVE.ORG link : CVE-2026-15811
JSON object : View
Products Affected
No product.
CWE
CWE-212
Improper Removal of Sensitive Information Before Storage or Transfer