A vulnerability classified as critical has been found in D-Link DAR-7000 up to 20240912. Affected is an unknown function of the file /view/DBManage/Backup_Server_commit.php. The manipulation of the argument host leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
                
            References
                    | Link | Resource | 
|---|---|
| https://github.com/mhtcshe/cve/blob/main/cve.md | Exploit Third Party Advisory | 
| https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354 | Vendor Advisory | 
| https://vuldb.com/?ctiid.278154 | Permissions Required | 
| https://vuldb.com/?id.278154 | Permissions Required | 
| https://vuldb.com/?submit.407023 | Third Party Advisory | 
| https://www.dlink.com/ | Product | 
Configurations
                    Configuration 1 (hide)
| AND | 
            
            
 
  | 
    
History
                    23 Sep 2024, 17:29
| Type | Values Removed | Values Added | 
|---|---|---|
| References | () https://github.com/mhtcshe/cve/blob/main/cve.md - Exploit, Third Party Advisory | |
| References | () https://supportannouncement.us.dlink.com/security/publication.aspx?name=SAP10354 - Vendor Advisory | |
| References | () https://vuldb.com/?ctiid.278154 - Permissions Required | |
| References | () https://vuldb.com/?id.278154 - Permissions Required | |
| References | () https://vuldb.com/?submit.407023 - Third Party Advisory | |
| References | () https://www.dlink.com/ - Product | |
| CPE | cpe:2.3:h:dlink:dar-7000:-:*:*:*:*:*:*:* cpe:2.3:o:dlink:dar-7000_firmware:*:*:*:*:*:*:*:*  | 
|
| First Time | 
        
        Dlink dar-7000
         Dlink dar-7000 Firmware Dlink  | 
|
| CVSS | 
        v2 :  v3 :  | 
    
        v2 : 6.5
         v3 : 9.8  | 
20 Sep 2024, 12:30
| Type | Values Removed | Values Added | 
|---|---|---|
| Summary | 
        
        
  | 
19 Sep 2024, 21:15
| Type | Values Removed | Values Added | 
|---|---|---|
| New CVE | 
Information
                Published : 2024-09-19 21:15
Updated : 2024-09-23 17:29
NVD link : CVE-2024-9004
Mitre link : CVE-2024-9004
CVE.ORG link : CVE-2024-9004
JSON object : View
Products Affected
                dlink
- dar-7000
 - dar-7000_firmware
 
CWE
                
                    
                        
                        CWE-78
                        
            Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')