CVE-2024-4121

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
Link Resource
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261864 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261864 Third Party Advisory VDB Entry
https://vuldb.com/?submit.317826 Third Party Advisory VDB Entry
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md Exploit Third Party Advisory
https://vuldb.com/?ctiid.261864 Permissions Required Third Party Advisory VDB Entry
https://vuldb.com/?id.261864 Third Party Advisory VDB Entry
https://vuldb.com/?submit.317826 Third Party Advisory VDB Entry
Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*

History

15 Jan 2025, 18:43

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.261864 - () https://vuldb.com/?ctiid.261864 - Permissions Required, Third Party Advisory, VDB Entry
References () https://vuldb.com/?id.261864 - () https://vuldb.com/?id.261864 - Third Party Advisory, VDB Entry
References () https://vuldb.com/?submit.317826 - () https://vuldb.com/?submit.317826 - Third Party Advisory, VDB Entry
CPE cpe:2.3:o:tenda:w15e_firmware:15.11.0.14:*:*:*:*:*:*:*
cpe:2.3:h:tenda:w15e:-:*:*:*:*:*:*:*
CWE CWE-787
First Time Tenda w15e
Tenda
Tenda w15e Firmware

21 Nov 2024, 09:42

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W15Ev1.0/formQOSRuleDel.md -
References () https://vuldb.com/?ctiid.261864 - () https://vuldb.com/?ctiid.261864 -
References () https://vuldb.com/?id.261864 - () https://vuldb.com/?id.261864 -
References () https://vuldb.com/?submit.317826 - () https://vuldb.com/?submit.317826 -

14 May 2024, 15:42

Type Values Removed Values Added
Summary
  • (es) Una vulnerabilidad ha sido encontrada en Tenda W15E 15.11.0.14 y clasificada como crítica. La función formQOSRuleDel es afectada por la vulnerabilidad. La manipulación del argumento qosIndex provoca un desbordamiento de búfer en la región stack de la memoria. Es posible lanzar el ataque de forma remota. El identificador de esta vulnerabilidad es VDB-261864. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera.

24 Apr 2024, 18:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-04-24 18:15

Updated : 2025-01-15 18:43


NVD link : CVE-2024-4121

Mitre link : CVE-2024-4121

CVE.ORG link : CVE-2024-4121


JSON object : View

Products Affected

tenda

  • w15e
  • w15e_firmware
CWE
CWE-121

Stack-based Buffer Overflow

CWE-787

Out-of-bounds Write