CVE-2024-2808

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*
cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*

History

21 Nov 2024, 09:10

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md - Exploit, Third Party Advisory () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md - Exploit, Third Party Advisory
References () https://vuldb.com/?ctiid.257663 - Permissions Required () https://vuldb.com/?ctiid.257663 - Permissions Required
References () https://vuldb.com/?id.257663 - Third Party Advisory () https://vuldb.com/?id.257663 - Third Party Advisory
CVSS v2 : 9.0
v3 : 9.8
v2 : 9.0
v3 : 8.8

26 Mar 2024, 03:13

Type Values Removed Values Added
References () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md - () https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC15/V1.0%20V15.03.20_multi/formQuickIndex.md - Exploit, Third Party Advisory
References () https://vuldb.com/?id.257663 - () https://vuldb.com/?id.257663 - Third Party Advisory
References () https://vuldb.com/?ctiid.257663 - () https://vuldb.com/?ctiid.257663 - Permissions Required
First Time Tenda
Tenda ac15
Tenda ac15 Firmware
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 9.8
CPE cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*
cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*

22 Mar 2024, 05:15

Type Values Removed Values Added
New CVE

Information

Published : 2024-03-22 05:15

Updated : 2024-11-21 09:10


NVD link : CVE-2024-2808

Mitre link : CVE-2024-2808

CVE.ORG link : CVE-2024-2808


JSON object : View

Products Affected

tenda

  • ac15
  • ac15_firmware
CWE
CWE-121

Stack-based Buffer Overflow