CVE-2023-29412

CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.
Configurations

Configuration 1 (hide)

AND
cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*
OR cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*
cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*
OR cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*
cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*

History

21 Nov 2024, 07:57

Type Values Removed Values Added
References () https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf - Mitigation, Patch, Vendor Advisory () https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf - Mitigation, Patch, Vendor Advisory

12 Jun 2024, 13:15

Type Values Removed Values Added
Summary (en) A CWE-78: Improper Handling of Case Sensitivity vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface. (en) CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when manipulating internal methods through Java RMI interface.

28 Apr 2023, 13:30

Type Values Removed Values Added
First Time Schneider-electric
Microsoft
Microsoft windows Server 2022
Schneider-electric apc Easy Ups Online Monitoring Software
Schneider-electric easy Ups Online Monitoring Software
Microsoft windows Server 2016
Microsoft windows Server 2019
Microsoft windows 10
Microsoft windows 11
CPE cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*
cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*
cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 9.8
References (MISC) https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf - (MISC) https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-04.pdf - Mitigation, Patch, Vendor Advisory

18 Apr 2023, 21:25

Type Values Removed Values Added
New CVE

Information

Published : 2023-04-18 21:15

Updated : 2024-11-21 07:57


NVD link : CVE-2023-29412

Mitre link : CVE-2023-29412

CVE.ORG link : CVE-2023-29412


JSON object : View

Products Affected

microsoft

  • windows_server_2022
  • windows_server_2019
  • windows_11
  • windows_server_2016
  • windows_10

schneider-electric

  • easy_ups_online_monitoring_software
  • apc_easy_ups_online_monitoring_software
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')