An issue was discovered on Brother MFC-J491DW C1806180757 devices. The printer's web-interface password hash can be retrieved without authentication, because the response header of any failed login attempt returns an incomplete authorization cookie. The value of the authorization cookie is the MD5 hash of the password in hexadecimal. An attacker can easily derive the true MD5 hash from this, and use offline cracking attacks to obtain administrative access to the device.
                
            References
                    Configurations
                    No configuration.
History
                    08 Nov 2024, 17:35
| Type | Values Removed | Values Added | 
|---|---|---|
| CWE | CWE-276 | |
| Summary | 
 | |
| CVSS | v2 : v3 : | v2 : unknown v3 : 9.1 | 
07 Nov 2024, 18:15
| Type | Values Removed | Values Added | 
|---|---|---|
| New CVE | 
Information
                Published : 2024-11-07 18:15
Updated : 2024-11-08 19:01
NVD link : CVE-2019-20457
Mitre link : CVE-2019-20457
CVE.ORG link : CVE-2019-20457
JSON object : View
Products Affected
                No product.
CWE
                
                    
                        
                        CWE-276
                        
            Incorrect Default Permissions